1、AC OVERCURRENT U1, V1, W1, U2, V2, W2, F, F2: 交流过流ALPHA MAX LIMIT U1, V1, W1, U2, V2, W2, F, F2: 移相角 最大值限幅ALPHA MIN LIMIT U1, V1, W1, U2, V2, W2, F, F2: 移相角 最小值限幅AMC CCB COMM U1, V1, W1, U2, V2, W2, F, F2: AMC 板、CCB 板通讯错误AuxOnSeqTimeOut: 合辅助开关 超时BRAKE LIM: 速度控制器限幅BRIDGE CHANGING U1, V1, W1, U2, V2,
2、W2, F, F2: 整流桥换向错误CCB Exc NotRdyRun: 励磁 CCB 故障CCB INT SWVER ERR: CCB 或 AMC 板软件版本错误CCB POWERFAIL U1, V1, W1, U2, V2, W2, F, F2: CCB 板供电故障CCB ST1 NotRdyRun: 定子 1 CCB 故障CCB ST2 NotRdyRun: 定子 2 CCB 故障CCB1 COMM ERR: CCB1 板通讯故障CCB1 NOT FOUND: CCB1 板未发现CCB1 WATCHDOG: CCB1 硬锁故障CCB2 COMM ERR: CCB2 板通讯故障CCB2
3、NOT FOUND: CCB2 板未发现CCB2 WATCHDOG: CCB2 硬锁故障CCB3 COMM ERR: CCB3 板通讯故障CCB3 NOT FOUND: CCB3 板未发现CCB3 WATCHDOG: CCB3 硬锁故障CCB4 COMM ERR: CCB4 板通讯故障CCB4 NOT FOUND: CCB4 板未发现CCB4 WATCHDOG: CCB4 硬锁故障CH0LinkError: AMC3 板 CH0 通道通讯故障CH2LinkError: AMC3 板 CH2 通道通讯故障CommAux24VDCOff: 24V 操作电源故障CommonSafetySw: 驱动器
4、安全开关打开ConvAux230VACOff: 功放电源故障ConvCFan1Tripped: 角组主柜风机故障ConvCFan2Tripped: 星组主柜风机故障ConvFan1Ack: 角组主柜风机故障ConvFan1OvLoad: 角组主柜风机故障ConvFan2Ack: 星组主柜风机故障ConvFan2OvLoad: 星组主柜风机故障COSFII CTRL LIM: COSFII 控制限幅CSM TIME OUT U1, V1, W1, U2, V2, W2, F, F2: 电流计算超时DC OVERCURRENT U1, V1, W1, U2, V2, W2, F, F2: 直流过流
5、DDCS CH2 CommErr: 主/ 从 AMC3 板通讯报警DMON_DIODE_FLT: 二极管监视故障DRAW LIM: 速度控制器限幅到达Drive2TripReq: AMC CH2 通讯故障跳闸DrvstartSeqTimeOut: 启动故障DrvStop1SeqTimeOut: 停车 1 故障DrvStop2SeqTimeOut: 停车 2 故障EMERGENCY OFF: 紧急断电EMERGENCY STOP: 急停EXC 1 TRIP CCB: 励磁 CCB 跳闸EXC1 CCB ALARM: 励磁 CCB 板报警Exc1CtrlRel|BlkTOut: 励磁电流控制器未开
6、放ExcAux230VACOff: 励磁功放电源故障ExcCB NotClosed: 励磁接触器故障ExcContractorAck: 励磁接触器无反馈ExcFanOvload: 励磁柜风机故障ExcitEarthFault: 转子接地故障 FLUX CTRL LIM: 磁通控制器限幅到达FLUX D COR LIM: 磁通 D 轴分量限幅到达 FLUX Q COR LIM: 磁通 Q 轴分量限幅到达FLUXREF CTRL LIM: 磁通给定限幅到达FREQUENCY FAULT U1, V1, W1, U2, V2, W2, F, F2: 电源频率错误(高/ 低)FUSE TRIP U1,
7、 V1, W1, U2, V2, W2, F, F2: 正组或反组快熔故障GRAY IO BOARD ERR: NGRB 板故障GRAY IO NOT FOUND: NGRB 板通讯故障GRAY POS DIFF ERR: NGRB 板检测到位置滑动过大HVSupplyNotOK: 高压供电电路未准备好I D POS LIM: 矢量控制限幅I S REF LIM: 电流给定限幅到达IOAnalogChError: S800 模拟输入通道初始化/状态错误IOMokuleFault: S800 模块初始化/状态错误IOModulewarning: S800 模块初始化 /状态错误LOAD ANGL
8、E LIM: 负载角 限幅到达 LongZeroSpeedRun: 零速运行时间过长MCBAck: 高压开关未合上MCBTripPresignal: 主回路断路器故障MEAS UNIT BOARD U1, V1, W1, U2, V2, W2, F, F2: MUB0 或 MUB1 板通讯故障MUBfaultX: MUB 板通讯故障NoExtStartPermis: 励磁启动允许信号丢失NTAC IO BOARD ERR: NTAC 板故障NTAC IO NOT FOUND: NTAC 板通讯故障NATC POS DIFF ERR: NTAC 板检测到位置滑动过大OS SW CCB U1, V
9、1, W1, U2, V2, W2, F, F2: 操作系统故障(更换 CCB 板)OUT OF SYNC U1, V1, W1, U2, V2, W2, F, F2: 同步故障OVERSPEED: 过速OVERVOLTAGE PROT U1, V1, W1, U2, V2, W2, F, F2: 硬件过压保护继电器动作PAI COMM U1, V1, W1, U2, V2, W2, F, F2: PAI 板通讯故障PAI FIRING INST U1, V1, W1, U2, V2, W2, F, F2: 触发脉冲故障PAI GDR FB U1, V1, W1, U2, V2, W2, F,
10、 F2: GDR 板到 PAI 板反馈错误PAI IO Error: PAI 板与 AMC3 板通讯报警PAI OVERLOAD U1, V1, W1, U2, V2, W2, F, F2: PAI 板通讯过载PAI PWR LOW U1, V1, W1, U2, V2, W2, F, F2: PAI、GDR1、GDR2 板电源故障PanelLost: 本地控制丢失RdyRunSeqTimeOut: 系统启动超时RemoteAndTestMode: 测试模式下选择远程控制报警ROTOR STALLED: 堵转Sta1CtrlRel|BlkTOut: 角组电流控制器未开放Sta2CtrlRel|
11、BlkTOut: 星组电流控制器未开放StartUpPrevented: 启动允许信号丢失STATOR 1 MCB TRIP CCB: 角组 CCB 故障跳闸STATOR 1 TRIP CCB: 角组 CCB 故障跳闸STATOR 2 MCB TRIP CCB: 星组 CCB 故障跳闸STATOR 2 TRIP CCB: 星组 CCB 故障跳闸STATOR1 CCB ALARM: CCB 板报警(u1, v1, w1)Stator1Aux230VACOff: 角组功放电源故障Stator1EarthFault: 定子 1 接地故障STATOR2 CCB ALARM: CCB 板报警(u2, v2, w2)Stator2Aux230VACOff: 星组功放电源故障Stator2EarthFault: 定子 2 接地故障TORQUE OR SPEED LIM: 速度控制器限幅(过载)UNDERVOLTAGE U1, V1, W1, U2, V2, W2, F, F2: 欠压