1、1SPECIFICATION BOOK FOR AIR REFRIGERANT DRIERJingjiang Yangfan Machine Manufacturing Co., Ltd1、 ApplicationThere is a lot of steam in the wet and hot atmosphere, this AIR REFRIGERANT DRIER can cool down air and then separate out condensate water. Using in boat, this device can prevent the wet air ru
2、sting the marine pipe. It can filter and clean air also.When the atmosphere temperature is less than 2, please dont use this device.2When theres no air flowing in inlet and outlet, please close down the device. 2、 Main parametersModel: LKG0.5 Type : refrigerationRefrigerant medium : R401 Working Pre
3、.:1.0 MPa Power source:220V,60Hz Dew point of pre.:2-10Air inlet Temperature. :55 Capacity:36Nm3/h3、 Structure 3. Maintain1. The surface of condenser with wind cooling type easily paste on dust 、dirty and fibre , must blow and clean it by using compressing air termly.2. Must clean the automation wat
4、er drainage termly .3. When the effect of separate water become not good, please check according to the following ways.3a. check the automation water drainage was blocked up or not.b. check the cooling capacity was more than normal or not.c. check the temperature of air inlet was more than normal or not.d. check the cooling system was leakage or not.