1、Page: 1 of 5 2016/01/20 TO 2016/01/25 No. : KA/2016/C1575 Date : 2016/01/25 2016/01/20 : : : : : = : : : : Based on the performed tests on submitted samples, the test results of Cadmium, Lead, Mercury, Cr(VI), PBBs, PBDEs comply with the limits as set by RoHS Directive 2011/65/EU Annex II; recasting
2、 2002/95/EC. As specified by client, with reference to RoHS Directive 2011/65/EU Annex II to determine Cadmium, Lead, Mercury, Cr(VI), PBBs, PBDEs contents in the submitted sample. Sample Description Test Requested Sample Receiving Date Test Result(s) Conclusion 59-1, SAN CHIA, JEN TE, TAINAN CITY 7
3、1702, TAIWAN Style/Item No. ACRYLONITRILE-BUTADIENE-STYRENE COPOLYMER POLYLAC PA-757 Sample Submitted By CHI-MEI CORPORATION Test Report CHI-MEI CORPORATION The following sample(s) was/were submitted and identified by/on behalf of the client as: Test Method With reference to IEC 62321: 2008. Please
4、refer to next page(s). Testing Period SGS Taiwan Ltd. 台灣檢驗科技股份有限公司No. 61, Kai-Fa Road, Nanzih Export Processing Zone , Kaohsiung, Taiwan / 高雄市楠梓加工出口區開發61號 t + 886 (07)301 2121 f + 886 (07)3010867 Member of the SGS Group Unless otherwise stated the results shown in this test report refer only to the
5、 sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company. This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at and, for electronic format documents
6、, subject to Terms and Conditions for Electronic Documents at Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Companys findings at the time of its interv
7、ention only and within the limits of Clients instructions, if any. The Companys sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced exce
8、pt in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.Page: 2 of 5 No. : KA/2016/C1575 Date : 2016/01/25 59-1, SAN CHI
9、A, JEN TE, TAINAN CITY 71702, TAIWAN Test Report CHI-MEI CORPORATION Test Result(s) : Result No.1 mg/kg With reference to IEC 62321: 2008 and performed by ICP-AES. 2 n.d. 100 mg/kg With reference to IEC 62321: 2008 and performed by ICP-AES. 2 n.d. 1000 mg/kg With reference to IEC 62321: 2008 and per
10、formed by ICP-AES. 2 n.d. 1000 mg/kg With reference to IEC 62321: 2008 and performed by UV-VIS. 2 n.d. 1000 mg/kg - n.d. 1000 mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg - n.d. 1000 mg/kg
11、5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - mg/kg 5 n.d. - Dibromodiphenyl ether Decabromobiphenyl Sum of PBDEs With reference to IEC 62321: 2008 and performed by GC/MS. Dibromobiphenyl Tribromobiphenyl Tetrabromobi
12、phenyl Heptabromobiphenyl Octabromobiphenyl Nonabromobiphenyl Octabromodiphenyl ether Pentabromodiphenyl ether Tetrabromodiphenyl ether Tribromodiphenyl ether Heptabromodiphenyl ether Limit MDL Method Unit Hexavalent Chromium Cr(VI) Sum of PBBs Test Item(s) Cadmium (Cd) Monobromodiphenyl ether Nonab
13、romodiphenyl ether Decabromodiphenyl ether Lead (Pb) Pentabromobiphenyl Monobromobiphenyl Hexabromodiphenyl ether Hexabromobiphenyl Mercury (Hg) PART NAME No.1 NATURE ACRYLONITRILE-BUTADIENE-STYRENE COPOLYMER SGS Taiwan Ltd. 台灣檢驗科技股份有限公司No. 61, Kai-Fa Road, Nanzih Export Processing Zone , Kaohsiung,
14、 Taiwan / 高雄市楠梓加工出口區開發61號 t + 886 (07)301 2121 f + 886 (07)3010867 Member of the SGS Group Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company. This d
15、ocument is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at Attention is drawn to the limitation of liability, indemnification
16、 and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Companys findings at the time of its intervention only and within the limits of Clients instructions, if any. The Companys sole responsibility is to its Client and this doc
17、ument does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content o
18、r appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.Page: 3 of 5 No. : KA/2016/C1575 Date : 2016/01/25 59-1, SAN CHIA, JEN TE, TAINAN CITY 71702, TAIWAN Test Report CHI-MEI CORPORATION 1. 2. 3. 5. 6. This report supersedes all previous documents
19、 bearing the test report number KA/201X/XXXXX. This is the additional test report of KA/201X/XXXXX which was issued on yyyy/mm/dd. Please refer to KA/201X/XXXXX for original information. mg/kg = ppm ;0.1wt% = 1000ppm Note : n.d. = Not Detected MDL = Method Detection Limit SGS Taiwan Ltd. 台灣檢驗科技股份有限公
20、司No. 61, Kai-Fa Road, Nanzih Export Processing Zone , Kaohsiung, Taiwan / 高雄市楠梓加工出口區開發61號 t + 886 (07)301 2121 f + 886 (07)3010867 Member of the SGS Group Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except
21、in full, without prior written permission of the Company. This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at At
22、tention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Companys findings at the time of its intervention only and within the limits of Clients instructions, if any
23、. The Companys sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any un
24、authorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.Page: 4 of 5 No. : KA/2016/C1575 Date : 2016/01/25 59-1, SAN CHIA, JEN TE, TAINAN CITY 71702, TAIWAN Test Report CHI-MEI CORPORAT
25、ION Note* :(1) For non-metallic material, add alkaline digestion reagent and heat to 9095 . (2) For metallic material, add pure water and heat to boiling. 1) These samples were dissolved totally by pre-conditioning method according to below flow chart. (Cr6+ test method excluded ) 2) Name of the per
26、son who made measurement: Alex Chang 3) Name of the person in charge of measurement: Ray Chang Cr 6 Sample Material Digestion Acid Steel, copper, aluminum, solder Aqua regia, HNO 3, HCl, HF, H2O2 Glass HNO 3/HF Gold, platinum, palladium, ceramic Aqua regia Silver HNO 3 Plastic H 2SO 4, H 2O2, HNO 3,
27、 HCl Others Any acid to total digestion Pb 、 Cd Solution ICP-AES Acid digestion by suitable acid depended on different sample material (as below table) Filtration Residue 1) Alkali Fusion 2) HCl to dissolve Sample Measurement Cutting / Preparation Microwave digestion with HNO 3 /HCl/HF Heat to appro
28、priate temperature to extract Cool, filter digestate through filter Add diphenyl-carbazide for color development Measure the absorbance at 540 nm by UV-VIS Add appropriate amount of digestion reagent Hg SGS Taiwan Ltd. 台灣檢驗科技股份有限公司No. 61, Kai-Fa Road, Nanzih Export Processing Zone , Kaohsiung, Taiwa
29、n / 高雄市楠梓加工出口區開發61號 t + 886 (07)301 2121 f + 886 (07)3010867 Member of the SGS Group Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company. This documen
30、t is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at Attention is drawn to the limitation of liability, indemnification and j
31、urisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Companys findings at the time of its intervention only and within the limits of Clients instructions, if any. The Companys sole responsibility is to its Client and this document
32、does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appe
33、arance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.Page: 5 of 5 No. : KA/2016/C1575 Date : 2016/01/25 59-1, SAN CHIA, JEN TE, TAINAN CITY 71702, TAIWAN Test Report No. : KA/2016/C1575 Date : 2016/01/ PBB/PBDE analytical FLOW CHART 1) Name of the pers
34、on who made measurement: Anson Tsao 2) Name of the person in charge of measurement: Ray Chang First testing process Optional screen process Confirmation process Sample Screen analysis Issue Report Sample pretreatment Sample extraction/ Soxhlet method Concentrate/Dilute Extracted solution Analysis by
35、 GC/MS Filter SGS Taiwan Ltd. 台灣檢驗科技股份有限公司No. 61, Kai-Fa Road, Nanzih Export Processing Zone , Kaohsiung, Taiwan / 高雄市楠梓加工出口區開發61號 t + 886 (07)301 2121 f + 886 (07)3010867 Member of the SGS Group Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This
36、test report cannot be reproduced, except in full, without prior written permission of the Company. This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at and, for electronic format documents, subject to Terms and C
37、onditions for Electronic Documents at Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Companys findings at the time of its intervention only and within t
38、he limits of Clients instructions, if any. The Companys sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.