1、 Visual measurement of exterior parts sample color work instruction683QM-C-WI0315 Page 1 of 4 01.Apr.2009 Ver. 1.0 683QM-C-WI0315 g7092g2475g6523g12468g11352g7003g1226g708g11017g4388g7735g6122g13452g7735g709g1363g11004g2081g20047g11842g16760g7003g1226g11352g7389g6940g10268g7424g701 Only for referenc
2、e Writedg726Wu Chenren Deptg726QM/P/Lab Telg7263671 E Approvalg726Welch.Chen Deptg726QM/P/Lab Telg7263668 Emailg726W Release dateg72601.04.2009 1 Purpose Visually measure color consistency with master color at Spectra Light III and at natrue light enverionment 2 Scope W683 3 Terminology / Abbreviati
3、on D65 Average north sky daylight TL84 Narrow band fluorescent lamp “A” Incandescent lamp 4 Responsibility QM/P/Lab Test, result analysis and reporting 5 Description 5.1 Equipment Color booth of Spectra Light III with D65, A and TL84 illumination Master color 3M cloth (Super green baize 2011) 5.2 Vi
4、sual measurement of color at Spectra Light III (SPLIII) 5.2.1 Measurement description Clean color sample and master color with 3M cloth and place them side by side at SPLIII. They will be placed at a rotatable table, so we can adjust the angle of table to change the measuring angle. Master color and
5、 sample still Visual measurement of exterior parts sample color work instruction683QM-C-WI0315 Page 2 of 4 01.Apr.2009 Ver. 1.0 683QM-C-WI0315 g7092g2475g6523g12468g11352g7003g1226g708g11017g4388g7735g6122g13452g7735g709g1363g11004g2081g20047g11842g16760g7003g1226g11352g7389g6940g10268g7424g701 Only
6、 for reference be placed at same direction (for example, word in sample still is faced up or same direction when assembled to vehicle). Pull the curtain that surrounding at SPL III to prevent the test no be affected by outside light source. Select a type of illumination. They are D65, TL84 and “A”.
7、D65 is for general use and TL84 and A are mainly for metamerism measurement. Observer must dress dull gray cloth. The distance of observation from eyes to sample must be about 70 80cm with vertical direction to sample plate and master color. Rotate the table to 45, select illumination to D65 and eva
8、luate the color difference with scale listed at Table 1 and indicate the direction of deviation (Dark or light, yellow or blue, red or green). Rotate table to 25 and 75and repeat the evaluation. Repeat evaluation at TL84 and “A” illumination with 45for metamerism measurement. Record evaluation resul
9、t at Form Sheet 683QM-C-WI0135-FM001. 5.2.2 Evaluation The evaluation will be conducted taking into account the scale listed at table 1 and quadrant of indicated 683QM-C-WI0XXX-FMXXX color quadrant list Table 1: color difference scale and evaluation at SPLIII illumination Meaning Scale Evaluation No
10、 difference 0 OK Light difference 1 OK Small difference 2 OK Medium difference 3 OK 3-4 OK Pronounced difference 4 OK 4-5 Conditional OK Very pronounced difference 5 No OK 5.3 Visual measurement of color at natural light condition 5.3.1 Measurement condition definition Visual measurement of exterior
11、 parts sample color work instruction683QM-C-WI0315 Page 3 of 4 01.Apr.2009 Ver. 1.0 683QM-C-WI0315 g7092g2475g6523g12468g11352g7003g1226g708g11017g4388g7735g6122g13452g7735g709g1363g11004g2081g20047g11842g16760g7003g1226g11352g7389g6940g10268g7424g701 Only for reference Fig 1. Demonstration of measu
12、rement angles DS - top view, SS - Oblique view Fig 2. Demonstration of nature light environment 5.3.2 Measurement step description Close light of room if they are on. Place view table to the position showed at Fig 2. Place sample and master color at the face of 0or 70of table; Evaluate the color dif
13、ference with scale listed at Table 2 and indicate the direction of deviation (Dark or light, yellow or blue, red or green). Record evaluation result at Form Sheet 683QM-C-WI0135-FM001. 5.3.3 Evaluation The evaluation will be conducted taking into account the scale listed at table 2 and quadrant of i
14、ndicated at 683QM-C-WI0XXX-FMXXX color quadrant list. Table 2: color difference scale and evaluation at nature light environment Meaning Scale Evaluation No difference 0 OK Light difference 1 OK Small difference 2 OK Medium difference 3 OK 3-4 Conditional OK Pronounced difference 4 No OK 4-5 No OK V
15、ery pronounced difference 5 No OK 6 Records and references Visual measurement of exterior parts sample color work instruction683QM-C-WI0315 Page 4 of 4 01.Apr.2009 Ver. 1.0 683QM-C-WI0315 g7092g2475g6523g12468g11352g7003g1226g708g11017g4388g7735g6122g13452g7735g709g1363g11004g2081g20047g11842g16760g7003g1226g11352g7389g6940g10268g7424g701 Only for reference 6.1 Records Item Document number title Valid Responsible 1 683QM-C-WI0315-FM01 Record sheet of visual measurement 5 QM 6.2 Reference A5-20-207U Valoracion visual de piezas adosadas exteriores y probetas 7 Annx No.