1、2015年6月,Balloon Tibioplasty: A Useful Tool for Reduction of Tibial Plateau Depression Fractures 球囊成形术治疗胫骨平台塌陷性骨折,导师:查振刚 教授 学生:顾容赫,2,Schatzker type,3,The common fracture patterns encountered are split depression (OTA Type B3, Schatzker Type II) and lateral depression (OTA type B2,Schatzker type III).
2、They prevailing in elderly patients due to osteopenia or osteoporosis。,Schatzker II,Schatzker III,胫骨平台常见的Schatzker type II/III 骨折多见于骨质减少或骨质疏松的老年人。,Backgrounds,Numerous techniques have been described to treat depressed tibial plateau fractures. With all techniques, the depression needs to be elevated
3、 mechanically with the use of metallic instruments through bone windows.传统方法:切开在关节面塌陷下方开窗+金属棒撬拨+植骨填充+钢板内固定,Backgrounds,Backgrounds,shortage : Depending on the instrument used and the bone quality, elevating a depressed fragment may make the defect worse or lead to intra-articular penetration.不足 :1)直
4、接撬拨顶推创伤大。2) 因骨质疏松,撬拨容易加重骨折。3)植骨填充时,容易导致复位关节面 重 新塌陷或矫枉过正。,Method,A fragment locking T-plateballoon K-wires cortical screw 胫骨外侧锁定T形钢板球囊克氏针皮质骨螺钉,Method,Intraoperative fluoroscopic monitoring (side view) of the reduction process by balloon tibioplasty. Note the gradual elevation of the depressed articul
5、ar area (arrows).,术中C臂透视侧位片,显示球囊成形过程。注意观察塌陷平台的抬高过程(箭头),A、 75year-old man with displaced split depression type fracture in CT of the tibial plateau (Schatzker type II). 75岁,男,胫骨平台骨折, Schatzker II B、 Tibial plateau fractures Arthroscopic. 关节镜下胫骨平台Schatzker II 骨折表现,A,B,Patients,Patients,A、 A visual che
6、ck under the lateral meniscus or an arthroscopic assessment of anatomic joint reduction completes the reduction procedure 扩张球囊上抬塌陷的平台时,同时直视或关节镜下观察胫骨平台复位情况。 B、 X-ray after operation. 术后X线表现。,A,Patients,A、 Seventy-year-old woman with a displaced lateral tibial plateau fracture (Schatzker III, OTA B2.2
7、). B、After full weight bearing without correction loss and barely noticeable scar after minimal invasive approach. C、follow-up (21 months)and CT excluding osteolysis aroundthe bone substitute, clinically optimalresult with return to previous sports activities,A,B,C,Method,J Bone Joint Surg Am. 2014
8、Aug 6;96(15):1273-1279. Reduction and Stabilization of Depressed Articular Tibial Plateau Fractures: Comparison of Inflatable and Conventional Bone Tamps: Study of a Cadaver Model.,尸体上C臂透视下两种手术方法左图:球囊扩张复位塌陷胫骨平台右图 :传统金属棒撬拨复位法,Fluoroscopic images illustrating the reduction On the right is the lateral
9、cortical window with conventional tamp and on the left is the inflatable tamp.,The reduction quality,Number of pairs in which the reduction quality of the side treated with the inflatable bone tamp (IBT) was rated as better than, equivalent to, or worse than that on the contralateral control side re
10、duced with the conventional bone tamps (CBT), as determined with the three evaluation methods.,图中IBT代表球囊复位, CBT代表传统撬拨复位, 经透视、CT、直观行双盲评估, 结果:关节面复位效果球囊扩张组优于传统撬拨复位组,The reduction quality,Photographs of the fractured lateral tibial plateau surfaces before (Fig. 1-A) and after (Fig. 1-B) reduction with a
11、n inflatable tamp and before (Fig. 1-C) and after (Fig. 1-D) reduction with the conventional tamp on the contralateral side.,图A/C:胫骨平台压缩性骨折尸 体模型图B:球囊扩张复位后表面,平滑图D:金属棒撬拨复位后表面,粗糙软骨破损,J Bone Joint Surg Am. 2014 Aug 6;96(15):1273-1279.,The reduction quality,Median residual defect volume expressed as a pe
12、rcentage of the depressed defect volume for fourteen specimens treated with an inflatable bone tamp (IBT)and fourteen contralateral specimens treated with conventional bone tamps (CBT). The dispersion bars represent the inter quartile range.,图中红柱代表球囊复位组, 黑柱代表传统撬拨复位组, 结果:总体复位不良率球囊扩张组小于传统撬拨复位组,The sti
13、ffness and yield load,Median stiffness and yield load during static loading of fourteen specimens treated with an inflatable bone tamp (IBT) and fourteen contralateral specimens treated with conventional bone tamps (CBT). The dispersion bars repr-esent the interquartile range. .,图中I黑柱代表球囊复位, 红柱代表传统撬拨复位, 结果:静态负荷强度中刚度和屈服载荷球囊扩张组均强于传统撬拨复位组,Conclusions,inflatable bone tamp had better reduction: 1、smoother articular surface with less residual defect volume,2、exhibited less subsidence during cyclic loading and greater stiffness under static loading,谢谢!,Thanks for your attention,