1、 WARNINGThank you for your confidence in LDP LLC cameras! Please be sure to read the following before operating! Keep camera away from sunshine and moisture. The operating temperature is 10C to +50C (15F to 100F). Never use thinner solvents to clean. Do not obstruct or block cooling vents. Do not at
2、tempt to take apart camera. No user serviceable parts inside. Do not pull in or out the Compact Flash (CF) card when power is on. Do not record to the CF card when the battery is low. Do not power off the camera when the recording to the CF card.IntroductionTIR2 SpecificationsImage Gray level image
3、can be displayed on the LCD 256-level pseudo-colors image can be displayed NTSC Composite video output of image informationFreeze and Save Image captured can be frozen. Image can be stored in the CF card with 256 M storage Some parameters such as environment temperature, measurement range, and the o
4、riginal signal standard can be stored in the CF card. 8 seconds sound information can be recorded in the CF card 1000 images can be stored Images stored can be x2 and 4x zoomed inX-Nite TIR2 Infrared Thermal Imager Operation Manual- -1Replay Stored images can be replayed Image replayed can be multi-
5、spot measured, isotherm and area analyzed Voice annotation with the images Image stored In the CF cards and data info can be transmitted by the USB reader, and then analyzed by the software.Temperature Measurement Temperature measurements are displayed in Celsius. Two temperatures are automatically
6、displayed simultaneously: Maximum temperature and a user selectable temperature measurement point. User selectable temperature measurement of any spot on the screen is indicated by movable cross, which can be manipulated via camera joystick. Maximum temperature displayed automatically and indicated
7、on LCD viewing screen. Isotherm FunctionMenu Setting User can set a wide variety of functions displayed on the LCD viewing screen. Temperature calibration: Emissive and reflected ambient. Automatic, or based on user-input Area analysis: Max, Min and accurate temp for selected areas Multi-spot analys
8、is: 4-spot analysis for the frozen and stored images. Clock function.X-Nite TIR2 Infrared Thermal Imager Operation Manual- -2TIR2 Technical IndexDetector Type: Microbolometer Uncooled FPADetector Pixels: 320 x 240 pixelsSpectrum Range: 8-14 microns (8,000nm to 14,000nm)Temperature Range: -10C to + 3
9、50C (14F to 660F)Thermal Sensitivity: 0.08CSpecial Resolution: 1mRadTemperature Accuracy: 1C 1% (-10CX110C)2C 2% (110CX300C)Temperature Measurement Range:1.: F 0.68: -10 C - +110C2.: F 2.00: 110 C- + 300CLens: 40 mm Display: 4-inch TFT color LCDImage Storage: 256MB Compact Flash (CF) card can save 1
10、,000 images, parameters and voice notations.Image replay: Can replay saved images and measure temperatureVoice annotation: Voice notations can be replayed with the imagesInterface: USB CF reader included. Image and voice data may be transferred to PC for subsequent analysis with supplied software.Pa
11、lette: 256-level pseudo-colors. User can choose from predefined color palettes or create custom palettes.Battery: Rechargeable Sony Lithium Ion Batteries Included with worldwide 100 - 240 volt charger.Battery Life: More than two hours. A “Power“ message will appear at bottom left of LCD X-Nite TIR2
12、Infrared Thermal Imager Operation Manual- -3screen when battery is low and a voice alarm will notify was well.IRDET1 System StructureStandard fitting IRDET1 IR camera 1 Standard Lens 1 4inch LCD 1 Chargeable Battery 2 Battery Charger 1 256MB CF card 1 USB reader 1 Software for analysis 1 Waterproof
13、case 1X-Nite TIR2 Infrared Thermal Imager Operation Manual- -4OPERATIONIdentifying the parts1 72 83 94 105 116 1213 1714 1815 19161 Power 11 CF card2 Reset 12 Battery3 Set 13 Cold4 Play 14 Menu5 Save 15 Aperture6 Video Out 16 Lens Focus7 Open 17 Hot 8 Microphone 18 Freeze9 Grip belt 19 LCD10 Joystic
14、k 20 Power input20X-Nite TIR2 Infrared Thermal Imager Operation Manual- -5Explanation of Operation Key1. POWER: Power switch, Press this button to power unit on or off.2. RESET: Press this button after power on to recalibrate camera.3. SET: The camera can measure two heat ranges: xx xx and yy yy. If
15、 you do not anticipate needing the high temperature range, you should use the lower temperature band for higher accuracy. To use the higher temperature range, choose D2 on the software setting and rotate the lens from the 0.68 to the 2.0 setting.Note: If the camera operates for a long time, it may b
16、e necessary to recalibrate camera. Pick a uniform temperature background or place lens cover on camera. Then press the Reset button or turn unit Off/On to recalibrate camera.4. PLAY: When playing back saved pictures, use the Play button after highlighting the desired picture. 5. SAVE: To save a pict
17、ure, first capture picture using the Freeze button. Then press the Save button to save the image to the CF memory card. 6. VIDEO: A NTSC composite video signal is output on the RCA connector.7. HOT / COLD: Pressing the Hot or Cold button will bring up the high and low temperature display parameters.
18、 Set the Hot and Cold range to the temperature range of interest in order to create an optimum false color image. The camera measures 80,000 temperature measurement points simultaneously. These temperatures may be displayed as a false color image. Setting the correct temperature band will enable the
19、 user to see the false color image with the highest detail.8. FREEZE: Pressing the Freeze button will freeze the image on the monitor. To store the image, press the Save button after freezing the image.9. MIC: The has a microphone for adding a voice memo to each image.11. JOYSTICK: The joystick is u
20、sed for changing settings in the menus and reading temperatures on the screen.12. MENU: Pressing the Menu button brings up the menu on the viewing screen.Operation StepsBefore using the unit, it is necessary to let the unit calibrate itself and warm up the sensitive electronics. Please perform the f
21、ollowing sequence: Power on with the lens X-Nite TIR2 Infrared Thermal Imager Operation Manual- -6cap onWait for 30 seconds to allow the unit to calibrate and stabilizeTurn power offTurn power back onRemove Lens Cover1. Power onSwitch on, the screen will show the picture just as Fig 1 below after 30
22、 seconds. Fig 1The former number shows the temp of the cross in the center, and the latter one shows the max temp. The camera will automatically find the highest temperature point in view.2. Parameter Setting: Fig 2 Fig 3 Fig 4 Analysis File Setup Analysis File Setup SetupObj. Obj. Open Analysis Ana
23、lysisSpot Spot DeleteDate/TimeDate/TimeArea AreaIsotherm IsothermTamb TambPressing Menu will display the menu shown in Fig 2, Analysis, File and Set Up. By moving the joystick from left to right you will see the menu shown in Fig 3. Use the joystick to change the parameters and press Menu to enter t
24、he valueIf you are in the Fig 4 menu, pressing Menu again will bring up the menu shown in Fig 5. Use the joystick to set the parameters: Pallet, Isotherm Color, Multi-Spot/Area, Area Function, Data Background, Temp Unit, Audio Alarm and Voice Annotation. Fig 5+ 26.1 26.7X-Nite TIR2 Infrared Thermal
25、Imager Operation Manual- -7Setup Parameter:Palette: 3Isotherm Color: WhiteMulti Spot/Area: OnArea Function: MinData Background: SolidTemp Unit: CelsiusAudio Alarm: OffVoice Annotation: Off31.8 45.5Palette There are 8 preset palettes to view thermal images. Use the joystick to select the most appropr
26、iate palette for you application.Isotherm Color The isotherm color can be set to black, white or green.Multi-Spot / Area The Multi-Spot / Area option toggles the camera between measuring multiple spots or an area.Area Function Enter this menu, to choose Max, Min and Average temperature measurements
27、of the chosen area.Data background The menus can be set to display as solid or translucent menus over the thermal image.Audio Alarm The camera can be enabled to automatically sound an alarm if a preset temperature is exceeded. The temperature can be set in the menu _ See P16 to get how to set the al
28、arm value.Voice Annotation By enabling voice annotation, the camera will allow you to record an audio memo with each captured image.3.Temp MeasurementAdjust the aperture at F=0.68, when “F=D1” appears on the screen, you can move the joystick from up and down for calibration and press “menu” to enter
29、 “analysis”, and press “menu” again to enter “Object parameter”, to choose “emissivity”, then adjust the number by controlling the joystick.Uncovering the lens cover, you can camera the object. Two ways are available, dynamic real time temp measurement and static temp measurement.Notice: To keep the
30、 accuracy, you should cover the lens, and press “set”, then X-Nite TIR2 Infrared Thermal Imager Operation Manual- -8calibration again by controlling the joystick up and down.1) Dynamic real time temp measurement Adjust the lens to get a clear image, and then there are two numbers on the screen. The
31、former one shows the temp of the cross in the center, and the latter one shows the max temp. 2) Static temp measurementKeep the camera steady when you get a clear image, to press “freeze”, the image will be remain on the screen. By controlling the joystick to move the cross, the number is the temp o
32、f the cross.Moving the cross by turning the “joystick” up, down, left or right. The cross spot temperature is the left value on the right down corner. 3) Temperature calibration for Small object, Humidity, Distance. According to the thermal response attenuation to the objects far away, the distance
33、temp calibration function is set on TIR2. If the far object is smaller than 1CM2,0.5CM 2,0.25CM 2 , please start the distance calibration function. Press “Menu” Key = Enter into ”Analysis” menu. Press “Menu” again to enter into “Object Parameter setting menu“, adjust “Joystick” up or down, select “d
34、istance”; select the object in “0.120 “ by turning left or right by “Joystick“. Similar method to adjust different humidity or distance. Alarm Setting: Select Alarm by moving “Joystick “ up and down, moving it left and right to set alarm temperature. 4) Temperature RangeIf the object temperature is
35、beyond the temperature range, words like “+” will appear on the right down corner of the screen. It means that the measure range should be changed. Cover the lens cover, turn the aperture to “2.0”, press “set” key, adjust the “Joystick” to change “F=D1” to “F=D2”, point the IR camera to the target a
36、gain, the temperature measurement function is available again. If object with high temperature need to be measured, please turn the aperture to “1.4”, then add the high-temp lens, and cover the lens cover, press “set “, and choose “F=D3” by X-Nite TIR2 Infrared Thermal Imager Operation Manual- -9con
37、trolling the joystick, then you can do the high-temp measurement. The table below is for your reference: Range Measure Range Aperture F NoteF D1 -10 110 0.68 e1 (Standard Blackbody)F D2 110 300 2.0 e1 (Standard Blackbody)4.Image StorageWhen the image is stable, press “Save” key, and several seconds
38、later, the thermal images will be stored in the CF card. If the Record/Play switch is in “ON” state, Fig 6 will appear. If the operator needs no voice annotation/recording, pls press “Joystick”; the storage number on the left down corner will add one automatically. The IR camera will only store the
39、image. If the Voice Annotation function is needed, pls adjust the “Joystick” up, 8 seconds voice annotation can be recorded. Adjusting the “Joystick” down can check the recorded voice annotation. If the operator is not satisfied with the records, he can repeat the operation until the result is satis
40、fied. Press “Joystick “ again to exit for the next operation. Note: Each Infrared image will be stored after the saved images; the previously stored images will not be covered/replaced. 5.Replay or delete the images in the cameraFor replay state, press “Menu” =” File “ = “Open” (Fig 7), Enter saved
41、images directory as Fig8. Adjust “Joystick” to select one, press” Menu” again to display the saved image and data on the screen. The recorded voice annotation plays when the saved image is replayed. Analysis File SetupOpenDeleteVoice Up RecordDown PlayFig 6GUIDE08 GUIDE07 GUIDE06GUIDE05 GUIDE04 GUIDE03 Open FileGuide011 8/11