收藏 分享(赏)

VDA277汽车标准.pdf

上传人:精品资料 文档编号:9964928 上传时间:2019-09-23 格式:PDF 页数:4 大小:79.89KB
下载 相关 举报
VDA277汽车标准.pdf_第1页
第1页 / 共4页
VDA277汽车标准.pdf_第2页
第2页 / 共4页
VDA277汽车标准.pdf_第3页
第3页 / 共4页
VDA277汽车标准.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 1 Determination of Organic Emission of Non-metallic materials from vehicles Interior VDA 277 Contents 1. General 2. Test preparations 3. Testing sets and conditions 4. Attempt realization 5. Calibration 6. Evaluation 1. General 1.1 Purposes According to this test method, the organic emission from n

2、on-metallic materials is determined with direct or indirect influence for the passengers cell of automobiles stand. It measure the emission potential of a material, the sum of all release values of the emitted substances with gaschromatograph and detection with a Flame ionization detector. The test

3、operated by means of steam space analysis (Head Space technology) at temperature of 120C. 1.2 Requirements The accompanying sample, the respective requirements as well as special method is of the suitable specification to take drawing or the like. If materials are composed of different components, a

4、 separate check is required for every single material. 2. Test preparations Transport and storage of the tests has to occur in an aluminum coated Polyethylenbeutel. The sampling has immediately after incoming goods or in a condition, which corresponds to this, to take place. The times of the incomin

5、g goods and the sampling are to be labelled. There is no conditioning of the test as a rule. Except of it are physical materials (cotton, wood, leather, wool). These materials are dried before the weighted sample in the chopped up state for 24 hours with calcium chloride (CaCl 2 ). The test is to be

6、 inferred at the agreed place about the whole test cross section from the component. The samples are chopped up in pieces with a weight more than 10 mg and less than 25 mg, without the test warms itself up. If necessary, another test preparations can be also undertaken and such deviation from standa

7、rd should be mentioned in the final result. The test amount to be rocked to sleep is directed after the size of the Head Space of little glass whose least contents 5 ml must amount. Per 10 ml little glass volumes are to be rocked to sleep 1.000 g +0.001 g (i.e. maximum content error 0.1%) test mater

8、ial. Metal are to be removed before weighting. When metal parts are liable to organic substances, for example, varnish, pastes, should be separated mechanically at first and then to rock to sleep. 2 The weighted test particles become in a Head Space little glasses (least 3 little glasses per test),

9、then air-tighted with the use of a septums with the Teflon coating which points to the interior of the little glass. 3. Testing sets and conditions 3.1 testing sets Gaschromatograph for capillary column with Head Space Tester, flame ionization detector (FID) and calculator/ Integrator. WCOT-capillar

10、y dividing column with a separating phase from 100% Polyethylene glycol (so-called Wax type, e.g., DBWax, Carbowax.) 0.25 mm I.D., 0.25 m film thickness, 30-m length Analytic balance, in the order of 0.1 mg Microliter syringe, 5 l, sample in vitreous body 3.2 measuring conditions Stove temperature p

11、rogram GC: 3 minutes isotherm at 50C Heating at 200C with a rate of 12 K / min 4 minutes isotherm at 200C Injector temperature: 200C Detector temperature: 250C Split ratio: approx. 1: 20 Carrier gas: helium Middle carrier gas speed: approx. 22-27 cm /s. Remark: the substance 2,6-Di-tert-butyl-4-meth

12、ylphenol (BHT) must show a retention time smaller than 16 minutes. 4. Attempt realization The little glasses are tempered to the enrichment of the substances in the air standing about the test directly before the measurement 5 hours + 5 minutes with 120 + 1 C in the Head Space Tester and are analyze

13、d directly afterwards. At least 3 tests are to be analyzed in each case. The control value is determined by average signal value of at least 3 measurements with empty test little glasses. The dosage must run off in all analyses of the tests, the control value and the calibration solution identically

14、 and reproduceable. The separating column must be brought to the bake once per week for 15 minutes at maximum temperature. 5. Calibration For the quantitative determination of the total carbon emission as well as the amount of special single substances, calibration curve are compared with the method

15、 of the external standard. For the total carbon emission, acetone serves as a calibration substance, for the single substances and the respective materials. After installation of a new column and after changes in the device a basic calibration with 7 calibration concentration is to be carried out. I

16、n addition, a control calibration with at least 3 concentrations has to be carried out at least every 4 weeks. 3 For basic calibration, 7 calibration solutions of acetone with concentration of 0.1/0.5/1/5/10/50/100grams of acetone in per liter of n-Butanol is made. For the control calibration soluti

17、on at least three concentrations 0.5/5/50 grams of acetone per liter are required. It is to be guaranteed that in the used n-Butanol show no Peaks at the same time as acetone. For the single substances, calibration solution are to be produced in the same concentration like for the acetone-control ca

18、libration and in each case, a solvent is to be used which shows no peaks with the retention time of the relevant single substance and boiling point lies under 120C. All substances used for the calibration procedure should be checked at least each year to show quality. With the calibration measuremen

19、t with one 5 l - syringe in each case 2 l + 0.02 l (i.e. maximum injection error 1%) per 10 ml little glass volume in an empty, unlocked Head Space little glasses squirted. Specific attention should be paid to the fact that no air bubbles are in the cylinder when drawing the syringe. The little glas

20、s is closed directly after as under 2 described. The calibrated sample is kept at a moderate temperature for 1 hour with 120C in the Head space Tester and then analyzed in accordance with the general test specification, whereby the temperature program of the gaschromatograph can be broken off after

21、elution of the solvent. At least 3 measurements are to be carried out for each calibration solution. With the concentrations of the calibration solutions (in g/l), determined for the respective calibration substance, a straight line can be drawn, whose upward gradient represents the calibration fact

22、or k (k(G) for the least squares to take place. The coefficient of correlation K must be thereby larger than 0,995.) 6. Evaluation From the data of the gaschromatogram the total peak area as well as the surfaces of the peaks belonging to the single substance indicated in the design and/or TL must ha

23、ve to be extracted. For the computation of the total peak area only peaks are consulted, -their height greater than 10% of the triple value of the baseline is And -their area greater than 10% of the area of the Acetone peaks in the calibration solution with the concentration 0.5 g/l is The detection

24、 limit of the analysis procedure must deliver a peak area and a peak height which is in each case smaller than 10% of the respective value which will receive for acetone in analysis of a calibration solution concentration of 0.5 g/l acetone. The desired emission values result from the results of mea

25、surement as follow: Total carbon emission E G : Ascertained from the total peak area which has arisen in the analysis of the tests, and the calibration factor k (G) from the acetone calibration E G = Total peak area Peak area of control x 2 x 0.6204 K (G) The unit “ g carbon per g of sample “. 4 The

26、 factor two is originated from the relation of “ g of sample “ and arises by the fact that 1 g of sample, 2 l calibration solution are given in 10 ml little glass. The factor 0.6204 shows the weight proportion of carbon in acetone. Single material Emission Ei: Ascertained from the Peak area which ha

27、s arisen in the analysis of the tests for the single material in request i, and the calibration factor k (i) from the single material calibration Ei = Peak area of the single material i x 2 K (i) The unit “ g substance i per g of sample “. The factor two is originated from the relation of “ g of sam

28、ple “ and arises by the fact that for 1 g of sample, 2 l calibration solution are given in 10 ml little glass. For the results of 3 measurements of a part, not the average value, but all 3 measured values must fulfill the requirement. This is necessary to guarantee that at all places of the construction meet the requirements.

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 企业管理 > 管理学资料

本站链接:文库   一言   我酷   合作


客服QQ:2549714901微博号:道客多多官方知乎号:道客多多

经营许可证编号: 粤ICP备2021046453号世界地图

道客多多©版权所有2020-2025营业执照举报