1、Relion 615 series Feeder Protection and Control REF615 Modbus Point List ManualDocument ID: 1MRS756581 Issued: 2013-02-21 Revision: F Product version: 4.0 FP1 Copyright 2013 ABB. All rights reservedCopyright This document and parts thereof must not be reproduced or copied without written permission

2、from ABB, and the contents thereof must not be imparted to a third party, nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license. Trademarks ABB an

3、d Relion are registered trademarks of the ABB Group. All other brand or product names mentioned in this document may be trademarks or registered trademarks of their respective holders. Warranty Please inquire about the terms of warranty from your nearest ABB representative. http:/ The data, examples

4、 and diagrams in this manual are included solely for the concept or product description and are not to be deemed as a statement of guaranteed properties. All persons responsible for applying the equipment addressed in this manual must satisfy themselves that each intended application is suitable and

5、 acceptable, including that any applicable safety or other operational requirements are complied with. In particular, any risks in applications where a system failure and/ or product failure would create a risk for harm to property or persons (including but not limited to personal injuries or death)

6、 shall be the sole responsibility of the person or entity applying the equipment, and those so responsible are hereby requested to ensure that all measures are taken to exclude or mitigate such risks. This document has been carefully checked by ABB but deviations cannot be completely ruled out. In c

7、ase any errors are detected, the reader is kindly requested to notify the manufacturer. Other than under explicit contractual commitments, in no event shall ABB be responsible or liable for any loss or damage resulting from the use of this manual or the application of the equipment.Conformity This p

8、roduct complies with the directive of the Council of the European Communities on the approximation of the laws of the Member States relating to electromagnetic compatibility (EMC Directive 2004/108/EC) and concerning electrical equipment for use within specified voltage limits (Low-voltage directive

9、 2006/95/EC). This conformity is the result of tests conducted by ABB in accordance with the product standards EN 50263 and EN 60255-26 for the EMC directive, and with the product standards EN 60255-1 and EN 60255-27 for the low voltage directive. The product is designed in accordance with the inter

10、national standards of the IEC 60255 series.Table of contents Section 1 Introduction.7 This manual7 Intended audience7 Product documentation.7 Product documentation set7 Document revision history.8 Related documentation8 Symbols and conventions.9 Symbols.9 Document conventions9 Functions, codes and s

11、ymbols10 Section 2 Modbus data mappings13 Overview.13 Supported functions13 Indications15 CommonData116 LD0.DARREC1 AR state.16 LD0.LEDPTRC1 Global conditioning.16 LD0.TRPPTRC1 Protection trip conditioning (1).17 LD0.TRPPTRC2 Protection trip conditioning (2).17 LD0.CMMXU1 Phase current limit supervi

12、sion (1)17 LD0.RESCMMXU1 Residual current limit supervision (1).18 LD0.RESVMMXU1 Residual voltage limit supervision (1).18 LD0.LEDGGIO1 Indication LED states OFF/ColorX.18 LD0.LEDGGIO1 Indication LED states Color1/Color219 LD0.TCSSCBR1 Trip circuit supervision (1)20 LD0.TCSSCBR2 Trip circuit supervi

13、sion (2)20 LD0.VMMXU1 Phase voltage limit supervision (1)21 CTRL.DCSXSWI1 Disconnector 1 mom position21 CTRL.DCSXSWI2 Disconnector 2 mom position21 CTRL.DCSXSWI3 Disconnector 3 mom position21 CTRL.ESSXSWI1 Earth switch 1 mom position22 CTRL.CBCSWI1 Circuit breaker 1 mom position22 CTRL.ESSXSWI2 Eart

14、h switch 2 mom position22 CTRL.CBCSWI1 Circuit breaker 1 mom+mcd position.22 CTRL.CBCILO1 Circuit breaker 1 enable signals.23 CTRL.CCBRBRF1 Circuit breaker 1 failure protection23 CTRL.CBXCBR1 Circuit breaker 1 blocking signals.23 Table of contents REF615 1 Point List ManualLD0.EFPADM1 Admittance-bas

15、ed earth-fault protection (1)24 LD0.EFPADM2 Admittance-based earth-fault protection (2)24 LD0.EFPADM3 Admittance-based earth-fault protection (3)24 LD0.SSCBR1 Circuit breaker 1 condition monitoring24 LD0.PHLPTOC1 Phase overcurrent protection, low stage (1)25 LD0.PHHPTOC1 Phase overcurrent protection

16、, high stage (1)25 LD0.PHHPTOC2 Phase overcurrent protection, high stage (2)26 LD0.PHIPTOC1 Phase overcurrent protection, instantaneous stage (1).26 LD0.DEFLPDEF1 Directional earth-fault protection - low stage (1)27 LD0.DEFLPDEF2 Directional earth-fault protection - low stage (2)27 LD0.DEFHPDEF1 Dir

17、ectional earth-fault protection - high stage (1)27 LD0.EFLPTOC1 Non-directional earth-fault protection - low stage (1)28 LD0.EFLPTOC2 Non-directional earth-fault protection - low stage (2)28 LD0.EFHPTOC1 Non-directional earth-fault protection - high stage (1).28 LD0.EFIPTOC1 Non-directional earth-fa

18、ult protection - instantaneous stage (1).29 LD0.INTRPTEF1 Transient/intermittent earth-fault protection (1).29 LD0.PDNSPTOC1 Phase discontinuity protection (1).29 LD0.NSPTOC1 Negative-sequence overcurrent protection, stage 1.30 LD0.NSPTOC2 Negative-sequence overcurrent protection, stage 2.30 LD0.INR

19、PHAR1 Three-phase inrush detection.30 LD0.T1PTTR1 Thermal overload protection (1)31 LD0.ARCSARC1 Fault arc protection, stage 131 LD0.ARCSARC2 Fault arc protection, stage 231 LD0.ARCSARC3 Fault arc protection, stage 332 LD0.SEQRFUF1 Fuse failure protection.32 CTRL.CCRDIF1 Current circuit failure dete

20、ction.32 LD0.DPHLPDOC1 Three-phase directional overcurrent protection, low stage (1)32 Table of contents 2 REF615 Point List ManualLD0.DPHLPDOC2 Three-phase directional overcurrent protection, low stage (2)33 LD0.DPHHPDOC1 Three-phase directional overcurrent protection, high stage (1).33 LD0.DARREC1

21、 Autorecloser.34 LD0.PHPTOV1 Phase overvoltage protection (1).35 LD0.PHPTOV2 Phase overvoltage protection (2).36 LD0.PHPTOV3 Phase overvoltage protection (3).36 LD0.PSPTUV1 Positive-sequence undervoltage protection (1)36 LD0.NSPTOV1 Negative-sequence overvoltage protection (1)37 LD0.PHPTUV1 Phase un

22、dervoltage protection (1).37 LD0.PHPTUV2 Phase undervoltage protection (2).38 LD0.PHPTUV3 Phase undervoltage protection (3).38 LD0.ROVPTOV1 Residual overvoltage protection (1).39 LD0.ROVPTOV2 Residual overvoltage protection (2).39 LD0.ROVPTOV3 Residual overvoltage protection (3).39 LD0.WPWDE1 Wattme

23、tric-based earth-fault protection (1)39 LD0.WPWDE2 Wattmetric-based earth-fault protection (2)40 LD0.WPWDE3 Wattmetric-based earth-fault protection (3)40 LD0.HAEFPTOC1 Harmonics-based earth-fault protection (1)40 LD0.CMHAI1 Current total demand distortion.40 LD0.VMHAI1 Voltage total demand distortio

24、n.41 LD0.PH1QVVR1 PQ - Voltage variation signals.41 CTRL.DCXSWI1 Controllable discon. 1 mom position data41 CTRL.DCXSWI2 Controllable discon. 2 mom position data42 CTRL.ESXSWI1 Controllable earth switch 1 mom position42 LD0.XGGIO130 Physical I/O states (BIO card X130) 43 LD0.XGGIO120 Physical I/O st

25、ates (AIM card X120).43 LD0.XGGIO110 Physical I/O states (BIO card X110).44 LD0.XGGIO100 Physical I/O states (PSM card X100)45 LD0.XAGGIO130 Physical I/O states (AIM card XA130)45 LD0.MVGAPC1 Multipurpose binary inputs (1).45 LD0.MVGAPC2 Multipurpose binary inputs (2).46 LD0.SPCGGIO2 Multipurpose bi

26、nary output states (2).47 Indications in FE08.48 LD0.SECRSYN1 Synchrocheck (1).48 LD0.FRPFRQ1 Frequency protection (1)48 LD0.FRPFRQ2 Frequency protection (2)48 LD0.FRPFRQ3 Frequency protection (3)49 LD0.XGGIO130 Physical I/O states (BIO card X130) 49 LD0.XGGIO120 Physical I/O states (AIM card X120).

27、50 Table of contents REF615 3 Point List ManualLD0.XGGIO110 Physical I/O states (BIO card X110).50 LD0.XGGIO100 Physical I/O states (PSM card X100)51 LD0.XAGGIO130 Physical I/O states (AIM card XA130)52 Registers52 User definable registers Alt.1, visible on 3x and 4x.52 User definable bits Alt.2, vi

28、sible on 0x,1x,3x and 4x.53 SSR1 System status register 1 - device health.53 SSR2 System status register 2 - IED mode and state.54 SSR3 System status register 3 - data available 1 (client- dependent)54 SSR4 System status register 4 - data available 2 (client- dependent - user-definable)55 SSR5 Syste

29、m status register 5 - device alive register.55 SSR6 System status register 6 - control command status (client-dependent)56 LD0.DARREC1 Autorecloser values 56 LD0.CMMXU1 Phase current measurements (1) .57 LD0.RESCMMXU1 Residual current measurement (1) .57 LD0.RESVMMXU1 Residual voltage measurement (1

30、) .57 LD0.CMSQI1 Sequence of current measurements (1) .57 LD0.T1PTTR1 Thermal protection values (1)58 LD0.HAEFMHAI1 Current harmonics (1) .58 LD0.VMMXU1 Voltage measurements (1) .58 LD0.VMSQI1 Sequence of voltage measurements (1) 59 LD0.PEMMXU1 Three-phase power measurements59 LD0.FMMXU1 Frequency m

31、easurement.59 LD0.SECRSYN1 Synchrocheck59 Indication bits mirrored in registers60 LD0.PEMSTA1 Power measurement demand values (1) 60 LD0.VMSTA1 Voltage demand values (1) 60 LD0.RESVMSTA1 Residual voltage demand value (1) 61 LD0.RESCMSTA1 Residual current demand value (1) 62 LD0.CMSTA1 Phase current

32、demand values (1) .62 CTRL.CBCSWI1 Circuit breaker operation counter (1) 63 LD0.ARCSARCx1 Fault arc counters .64 LD0.DARREC1 Autorecloser counters .64 LD0.PEMMTR1 Three-phase energy measurements.64 System diagnostic values65 LD0.SSCBR1 Circuit-breaker condition monitoring values.65 LD0.PH1QVVR1 Shor

33、t duration voltage variations.65 LD0.CMHAI1 Current total demand distortion.66 LD0.VMHAI1 Voltage total demand distortion.67 Control structure 1.67 Control structure 2.68 Table of contents 4 REF615 Point List ManualControl structure 3.68 Control structure 4.68 Control structure 5.68 Control structur

34、e 6.69 Control structure 7.69 Control structure 8.69 Device ID string.69 IED Real-time clock (in local time mode) - read and write (synchronize).70 IED real-time clock (in UTC time mode) - read and write (synchronize).70 Time and reason for latest IED reset.70 Active parameter setting group - read a

35、nd write71 Event record structure.71 Fault record structure header75 Fault record data.76 Controls77 CTRL.CBCSWI1 Circuit breaker (1) control77 Reset, acknowledge and trigger points (A)77 LD0.LPHD1 IED warm reset78 LD0.SRGAPC1 Reset SRGAPC1 generic flip-flops78 LD0.SRGAPC2 Reset SRGAPC2 generic flip

36、-flops79 LD0.SPCGGIO1 Multipurpose binary outputs (1) .79 LD0.SPCGGIO2 Multipurpose binary outputs (2) .80 CTRL.DCCSWI1 Disconnector (1) control80 CTRL.DCCSWI2 Disconnector (2) control81 CTRL.ESCSWI1 Earth switch (1) control81 Section 3 Glossary.83 Table of contents REF615 5 Point List Manual6Sectio

37、n 1 Introduction 1.1 This manual The point list manual describes the outlook and properties of the data points specific to the IED. The manual should be used in conjunction with the corresponding communication protocol manual. 1.2 Intended audience This manual addresses the communication system engi

38、neer or system integrator responsible for pre-engineering and engineering for communication setup in a substation from an IED perspective. The system engineer or system integrator must have a basic knowledge of communication in protection and control systems and thorough knowledge of the specific co

39、mmunication protocol. 1.3 Product documentation 1.3.1 Product documentation set The application manual contains application descriptions and setting guidelines sorted per function. The manual can be used to find out when and for what purpose a typical protection function can be used. The manual can

40、also be used when calculating settings. The communication protocol manual describes a communication protocol supported by the IED. The manual concentrates on vendor-specific implementations. The engineering guide provides information for IEC 61850 engineering of the protection IEDs with PCM600 and I

41、ET600. This guide concentrates especially on the configuration of GOOSE communication with these tools. The guide can be used as a technical reference during the engineering phase, installation and commissioning phase, and during normal service. For more details on tool usage, see the PCM600 documen

42、tation. The engineering manual contains instructions on how to engineer the IEDs using the different tools in PCM600. The manual provides instructions on how to set up a PCM600 project and insert IEDs to the project structure. The manual also 1MRS756581 F Section 1 Introduction REF615 7 Point List M

43、anualrecommends a sequence for engineering of protection and control functions, LHMI functions as well as communication engineering for IEC 61850 and other supported protocols. The installation manual contains instructions on how to install the IED. The manual provides procedures for mechanical and

44、electrical installation. The chapters are organized in chronological order in which the IED should be installed. The operation manual contains instructions on how to operate the IED once it has been commissioned. The manual provides instructions for monitoring, controlling and setting the IED. The m

45、anual also describes how to identify disturbances and how to view calculated and measured power grid data to determine the cause of a fault. The point list manual describes the outlook and properties of the data points specific to the IED. The manual should be used in conjunction with the correspond

46、ing communication protocol manual. The technical manual contains application and functionality descriptions and lists function blocks, logic diagrams, input and output signals, setting parameters and technical data sorted per function. The manual can be used as a technical reference during the engin

47、eering phase, installation and commissioning phase, and during normal service. 1.3.2 Document revision history Document revision/date Product version History A/2008-07-02 1.1 First release B/2009-03-04 2.0 Content updated to correspond to the product version C/2009-07-03 2.0 Content updated D/2010-0

48、6-11 3.0 Content updated to correspond to the product version E/2012-05-11 4.0 Content updated to correspond to the product version F/2013-02-21 4.0 FP1 Content updated to correspond to the product series version Download the latest documents from the ABB Website http:/ 1.3.3 Related documentation N

49、ame of the document Document ID Modbus Communication Protocol Manual 1MRS756468 Section 1 1MRS756581 F Introduction 8 REF615 Point List Manual1.4 Symbols and conventions 1.4.1 Symbols The caution icon indicates important information or warning related to the concept discussed in the text. It might indicate the presence of a hazard which could result in corruption of software or damage to equipment or property. The information icon alerts the reader of important facts and conditions. The tip icon indicates advic