1、,SIMATIC PCS 7,System Overview,A,A,A,C,C,C,A,A,B,B,B,B,?,?,?,?,Overview of Functions of an Entire Plant,Totally Integrated Automation,(,Batch,Warm area,Cold end,Central control room,Local control room,Office,Local control room,Engineering,(,Tele Service,SIMATIC PCS 7,SIMATIC Controller,SIWAREX M,SIT
2、RANS P,SIPART DR,SIMODRIVE POSMO,SINUMERIK SIMODRIVE,SIMOVERT MASTERDRIVES,SIMATIC S7/M7-300,SIMODRIVE SENSOR,MICROMASTER,OP 032 S,SIMATIC HMI,PROFIBUS DP,PROFIBUS PA,1FT6/1FK6,SIMATIC,HMI,Controller,Distributed I/O,Field,Communication,Software,Data Management,Communication,Database,Vertical Integra
3、tion,Horizontal Integration,A,A,A,C,C,C,A,A,B,B,B,B,?,?,?,?,The Classic Solution,A,A,A,C,C,C,A,A,B,B,B,B,?,?,?,?,PLC,PLC,PCS,PC,The New SIMATIC Control System,A,A,A,C,C,C,A,A,B,B,B,B,?,?,?,?,PLC,PLC,PCS,PC,SIMATIC Process Control System 7,What Is Process Control?,AutomationtechnologyMeasurementClose
4、d-Loop Con.Open-Loop Con.etc.,HMI Displaying Operating Loggingetc.,Communicationtechnology,+,AS,OS,Bus,Seamless Integration of Todays Systems,TELEPERM M,SIMATIC S5/COROS,SIMATIC Process Control System 7,SIMATIC PCS,A New PLC Generation with Integrated Process Control Functionality,S7 400,SIMATIC Con
5、trollers,S7 300,SIMATIC M7,SIMATIC C7,+,SIMATIC PCS 7 Automation Systems: S7 Controller/CPU 414-3 to 417-4H,24 VDC power supply or 115/230 VACCPU with a memory card and integrated interfaces for PROFIBUS-DP and MPICommunications processor for the PROFIBUS system bus or Industrial EthernetAdditional
6、communications processors for distributed I/Os to the PROFIBUS DP or SM 421 digital input for cabinet messages,Configuration: modular, no fan,Complete I/O Module Spectrum,SIMATIC Distributed I/Os,S,0,1,2,3,4,5,6,7,0,1,2,3,4,5,6,7,Standard I/O modules (A class),I/O modules with diagnostics (B class),
7、Ex(i) modules,Functional modules (e.g. closed-loop controllers and counters),S,0,1,2,3,4,5,6,7,0,1,2,3,4,5,6,7,SIMATIC PCS 7 Automation Systems: Distributed I/Os,Ind. Ethernet,AS 414, AS 416, AS 417,ET 200 M,ET 200 M EEx ib,Field devices,SIMATIC Distributed I/O - ET 200MStandard I/O modulesIntrinsic
8、ally safe modules EEx ibFunction modules,PROFIBUS DP,Properties ET 200MUp to 8 modules per stationUp to 61 analog values per stationHigh channel density and functionalityRemoving and connecting modules possible during operationDegree of protection IP 20,SIMATIC PCS 7 Automation Systems: Standard Sig
9、nal Modules in ET 200M,Non-diagnostics-capable modules (Class A) Digital input 16 channels, 24 VDCDigital output 16 channels, 24 VDC / 0.5 ADiagnostics-capable modules (Class B) Digital input 16 channels, 24 VDC Digital output 8 channels, 24 VDC / 0.5 A, Can be made redundant (redundant output on a
10、simple actuator) Analog input 8 channels, 14 bit Analog output 4 channels, 12 bit,Ind. Ethernet,AS 414, AS 416, AS 417,ET 200 M,PROFIBUS-DP,Advanced support for redundant I/O modules,Redundancy configurable separately for every module mixture of red. & non-red. modules in one CPU possible no specifi
11、c logic in CFCs necessary - channel switch-over done automatically by the system,I/O-redundancy for selected modules of the ET 200M line,Configuration via Browser,I/O module,sensor,AS 414 H AS 417 H,PROFIBUS-DP,redundant I/O module,I/O modules that support new redundancy concept,fail safe:DI 14 x DC
12、24 V (6ES7326-1BK00-0AB0) DI 8 x NAMUR EEx ib (6ES7 326-1RF00-0AB0)DO 10 x DC24V/2A (6ES7 326-2BF00-0AB0)AI 6 x 13Bit (6ES7 336-1HE00-0AB0)standard ET200M line:DI 16 x DC24V, Diagnosis (6ES7 321-7BH00-0AB0)DO 32 x DC24V/0.5A (6ES7 322-1BL00-0AA0)AI 8 x 12Bit (6ES7 331-7KF02-0AB0) AO support in progr
13、essproject specific solutions, e.g.:AO 4 x 12 Bit (6ES7 332-5HD01-0AB0) DO 8 x DC24V/0.5A (6ES7 322-8BF00-0AB0) DO 16 x DC24V/0.5A (6ES7 322-8BH00-0AB0),SIMATIC PCS 7 Automation Systems: ET 200M “Hot Swapping” Mounting Rack,ET 200 M,Bus module 1 (for IM 153),Bus module 2 2 I/O mod. 40 mm,Bus module
14、3 1 I/O mod. 80 mm,Rail,SIMATIC S7-400F/FH with ET 200M,Standard cabinet (2000 x 800 x 400 mm)Conforms to CECompletely pre-wiredAS 414, AS 416 With PROFIBUS DP and system busIP 40 degree of protection (IP 54 optional)5 x ET 200 M with 8 modules each Power supply: DC 24 V single / redundant230 VACCap
15、acity (example for mixed operation): 20 x 8 = 160 analog values and20 x 16 = 320 binary values,SIMATIC PCS 7 Automation Systems: Cabinet Design - CPUs and I/Os,The New Generation of HMI Systems: WinCC,Open architecture,Price,WinCC,Standard Operator System,SIMATIC HMI,Communication via Fieldbus/Syste
16、m Bus: PROFIBUS, Industrial Ethernet and MPI,SIMATIC NET,AS-Interface,OS,OS,ES,MPI / PROFIBUS / Industrial Ethernet,PROFIBUS DP,SIMATIC NET - Which Bus for Which Task?,MPI (only for test purposes) Communication for small to medium-sized systems Integrated programming interface for the controller PRO
17、FIBUS (small configurations only) Fast, standardized fieldbus (EN 50170) Fast system bus for medium- to large-scale configurations Industrial Ethernet (recommended) System bus with high performance for large-scale configurations Communication with the corporate management level (TCP/IP),PROFIBUS PA,
18、PROFIBUS DP,Master (Class 1),Slaves (Field devices, distributed I/Os, lower-level PLCs, network transition to PROFIBUS PA),Master (Class 2),PROFIBUS PA,J,SIMATIC PCS 7 - Engineering Toolset,Special Process Industry Requirements: Integral OS-AS-ES System Architecture,Communication,Operator Interface,
19、Engineering Station,Controller,ES,OS,CCX,WIN CC,Ethernet,SIMATIC S7,Special Process Industry Requirements: Availability,High availability High quality Standard SIMATIC components Short MTTR Diagnostics functions Removing/inserting under power Process control message concept Redundancy CPU Module Com
20、munication,Special Process Industry Requirements: Integrated AS and OS Configuration,Y2,GF-LI,GFE-LI,SCHRI,GF,FW VORBEREITEN/STARTEN,V5,V4,V3,0000.0,MBAR,P4,0000.0,MBAR,P5,0000.0,MBAR,P6,0000.0,MBAR,P1,INERTGAS,ABLUFT1,ABLUFT2,ABLUFT3,V6,V1,Y1,V2,MBAR,PC,%,A1,0000.0,Reaktor 01,0000.0,%,000.0,%,000.0
21、,0000.0,M,produkt,M1,R1,FR,HD,AS,AU,FO,HT,AB,FR,Grundzustand,P-AUSGL.,0000,0000,F1,ES,Engineering System,SIMATIC PCS 7 - Automation Systems: Configuring with Function Blocks,PROFIBUS DP,AS 414, AS 416, AS 417,Central Engineering System (ES)CFC library: Substitute modules, for field devices and distr
22、ibuted peripherals,Picture Blocks for WinCC,network configuring: DP Master,OS,Industrial Ethernet,SIMOVERT,SIMOCODE,SIPART,SIPOS 3 MC,ET 200 M,Operating & Monitoring,Reporting,Reading measured values andWriting manipulated variables,Configuring,Configuring,ET 200 iS,ET 200 X,Special Process Industry
23、 Requirements: Top-Down Design Methodology,Special Process Industry Requirements: Standards,Library package for the process industry Standard batch package,Special Process Industry Requirements: Interface to the Plant Control Level,A,A,A,C,C,C,A,A,B,B,B,B,HC,ES,OS,Cornerstone,OLE,ODBC / DDE,File tra
24、nsfer,SIMATIC S7,WIN CC,Engineering,Ind. Ethernet,PROFIBUS,Instrum.,Drives,SIMATIC Process Control System 7 System-Wide Engineering,Summary (1),System-wide engineeringOS Batch AS and SPSen Remote I/O ET200 Networks FB library incl.- PROFIBUS devices- SIMOVERT- SIMOCODE- MicroMaster - .- SIPART- SIPO
25、S- SITRANS- SIWAREX- S5-95F failsafe - AS-interface & link- For more information about drivers, go to e.g.: http:/intra1.khe.siemens.de/infopage/,IT,Intranet / InternetOS client , OPC, atGlance,SPC, MES, ERP etc.,M,HART,Remote I/O,12 Mbit/s,H2 fieldbusPROFIBUS DP,high-speed fully redundant bus and ring field-proven (since 1992) IEC 61158,PLC,Ident. components & software tools!,ES,OS,AS,10/100 Mbit/s,System bus industrial Ethernet and high-speed Fast Ethernet ring fully redundant field-proven (since 1996),100 Mbit/s,PA,PA,PA,31,25 kbit/s,DP/PA,.,.,Summary (2),