1、More than safety.System ManualSafety System MGB-AR in combination with a locking moduleMGB-L1-AR-./MGB-L2-AR-.System Manual Safety System MGB-AR in Combination with a Locking ModuleContentsCorrect Use 3Exclusion of Liability and Warranty 4General Safety Instructions 4Function 5System overview 6Locki

2、ng module MGB-L1-AR-./MGB-L-AR-. 6Handle module MGB-H-. 6Escape release MGB-E-. (optional) 6Dimension drawing 7Mechanical release 8Lockout mechanism 9Escape release (optional) 9Installation 11Changing Actuating Direction for Doors Hinged on the Left 12Protection Against Environmental Effects 13Elect

3、rical Connection 14Safety in case of faults 15Fuse protection for power supply 15Requirements for connection cables 15Notes on cable laying 16Pin assignment and contact description 17Operation as separate device 18Operation in a CES-AR switch chain 19Information on operation in a CES-AR switch chain

4、 0Setup 21Teach-in operation 1System Status Table 23Technical Data 24Typical system times 5Troubleshooting 26Latching fault when actuating the escape release 6Fault reset 6Inspection and Service 27Declaration of Conformity 28System Manual Safety System MGB-AR in Combination with a Locking ModuleCorr

5、ect UseThe safety system MGB is an electromagnetic interlock device with guard lock-ing.The system comprises at least one locking module MGB-L1-AR-./MGB-L-AR-. and one handle module MGB-H.The locking module MGB-L1-AR-./MGB-L-AR-. can be integrated into a switch chain for the safety system CES-AR or

6、operated as a separate system.In combination with a separating safety guard and the machine control, this safety component prevents the safety guard from being opened while a dangerous machine movement is being performed.For the control system, this means thatstarting commands which cause hazardous

7、situations must become active only when the safety guard is in protective position and the guard locking is in locked position. The locked position of the guard locking must be released only when the haz-ardous situation is no longer present.Before safety components are used, a risk assessment must

8、be performed on the machine in accordance withEN ISO 1849-1, Safety of machinery. Safety related parts of control systems. General principles for design, Annex BEN ISO 1411, Safety of machinery. Risk assessment. Principles.Correct use includes compliance with the relevant requirements for installati

9、on and operation, in particularEN ISO 1489-1, Safety of machinery. Safety related parts of control systems. General principles for designEN 1088, Safety of machinery. Interlocking devices associated with guards. Principles for design and selectionEN 6004-1, Safety of machinery. Electrical equipment

10、of machines. General requirements.The safety system MGB can only be combined with the intended modules in the MGB system family.On the modification of system components, EUCHNER provides no warranty for safe function.Connection of several devices in a CES-AR switch chain is permitted only using devi

11、ces intended for series connection with the CES-AR. Please check this in the operating instructions of the respective device. For detailed information on opera-tion in a CES-AR switch chain, please see the related CES-AR system manual.Important!The user is responsible for safe integration of the dev

12、ice in a safe overall system. For this purpose the overall system must be validated, e.g. in accor-dance with EN ISO 1849-.The permissible operating parameters must be observed for correct use (see Technical data).If a product data sheet is included with the product, the information on the data shee

13、t applies in case of discrepancies with the operating instructions.System Manual Safety System MGB-AR in Combination with a Locking Module4Important!In the estimation of the PL for the overall system, a maximum value of 100 years can be assumed for the MTTFdaccording to the limit value in EN ISO 184

14、9-1:008, Section 4.5. This corresponds to a minimum value for the PFHdof .47 x 10-8/h.When up to 10 devices are connected in series, these limit values can be assumed for the entire switch chain as a subsystem. As a subsystem, this switch chain achieves PL e. Exclusion of Liability and WarrantyIn ca

15、se of failure to comply with the conditions for correct use stated above, or if the safety instructions are not followed, or if any servicing is not performed as required, liability will be excluded and the warranty void.General Safety InstructionsSafety switches fulfill personal protection function

16、s. Incorrect installation or tamper-ing can lead to fatal injuries to personnel.Check the safe function of the safety guard particularlyafter any setup workafter the replacement of an MGB componentafter an extended period without useafter every faultIndependent of these checks, the safe function of

17、the safety guard should be checked at suitable intervals as part of the maintenance schedule.Warning!Loss of safety function in the event of incorrect connection or incorrect use. Safety switches must not be bypassed (bridging of contacts), turned away, removed or otherwise rendered ineffective.On t

18、his topic pay attention in particular to the measures for reducing the pos-sibility of bypassing from EN 1088:1995+A:008, section 5.7.The switching operation is only allowed to be triggered by the intended han-dle module MGB-H. that is positively fastened to the safety guard.The device is only allow

19、ed to be installed and placed in operation by authorized personnel who are familiar with the correct handling of safety components who are familiar with the applicable EMC regulationswho are familiar with the applicable regulations on health and safety who have read and understood the operating inst

20、ructions and the system manualSystem Manual Safety System MGB-AR in Combination with a Locking Module5Important!Prior to use read the operating instructions and the system manual, and keep these in a safe place. Ensure the operating instructions and the system manual are always available during moun

21、ting, setup and servicing. EUCHNER cannot provide any warranty in relation to the readability of the CD for the storage pe-riod required. For this reason you should archive a printed copy of the system manual. If you should lose the operating instructions or the system manual, you can download these

22、 documents from www.EUCHNER.de.FunctionTogether with a handle module, the locking module makes it possible to lock moveable safety guards. The combination also serves as a mechanical door stop at the same time.The following switch-on condition applies for the safety outputs OAand OB(see also System

23、status table):Safety guard closedBolt tongue inserted in the locking moduleLocking arm in locking positionBoth safety inputs (IA and IB) must be onThe locking module detects the position of the safety guard and the position of the bolt tongue. The position of the locking arm is also monitored.The bo

24、lt tongue in the handle module is retracted and extended by actuating the door handle.When the bolt tongue is fully inserted in the locking module, the locking arm locks the bolt tongue in this position. Depending on the version, this locking is by spring force or solenoid force.Version MGB-L1-AR-.T

25、he locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).Version MGB-L2-AR-.The locking arm is held in the locked position by solenoid force and is unlocked by spring force when the solenoid is switched off (open-circuit curre

26、nt principle).Warning!The safety guard can be opened immediately in the event of interruption of the solenoid power supply!Usage only in special cases in accordance with strict evaluation of the acci-dent risk (see EN 1088:1995+A:008, section 5.5).Typical case: If the risk of accidental locking insi

27、de a safety guard during a power failure is higher than the risk of ineffective guard locking.System Manual Safety System MGB-AR in Combination with a Locking Module6System overviewLocking module MGB-L1-AR-./MGB-L2-AR-.Figure 1: Locking module MGB-L1-AR-./MGB-L2-AR-.Handle module MGB-H-.Figure 2: Ha

28、ndle module MGB-H-.Escape release MGB-E-. (optional)Figure 3: Escape release MGB-E-.124536Key:1Cover for mechanical release2LED indicator3Terminals X -X54Locking arm5Auxiliary marking for maximum per-mitted mounting distance 6Depending on version: Cable entry M0x1.5 or plug con-nectorNote: Depending

29、 on the version, additional controls and indicators may be integrated into the cover and a mounting plate can be included. See enclosed data sheet.1234Key:1Door handle2Locking pins for housing cover and handle adjustment3Lockout bar4Bolt tongueNote: Depending on the version, a mounting plate can be

30、included. See enclosed data sheet.1 2 3 4 5Key:1Door handle2Setscrew3Cover4Actuation axis 8 x 8 mm5Protective sleeveNote: Depending on the version, a mounting plate can be included. See enclosed data sheet.System Manual Safety System MGB-AR in Combination with a Locking Module7Dimension drawingFigur

31、e 4: Dimension drawing, MGB fitted without optionial mounting platesyxz5172114404093113,5 110M20x1,5 (4x)19,2289,3AUFOPENCLOSEDZU4013015111404155,3401058,5110 8 x 87,56,586,515,41573,56,36,289,424510461089,477,592,516,5System Manual Safety System MGB-AR in Combination with a Locking Module8Mechanica

32、l releaseIn the event of service, the guard locking can be released with the mechanical release irrespective of the state of the solenoid (see Figure 5).The locking screw must be screwed back in and sealed after use (for example with sealing lacquer). Tightening torque 0.5 Nm.Undo locking screws.Lif

33、t locking arm using a screwdriver and actuate door handleImportant!The system enters into a latching fault when the mechanical release is actuated. See system status table on page , state signal sequence erroneous (DIA1 flashes six times).Note!The system might not enter into a latching fault if the

34、mechanical release is actu-ated very slowly.Figure 5: Mechanical release1.System Manual Safety System MGB-AR in Combination with a Locking Module9Lockout mechanismIf the lockout bar is pivoted out, the bolt tongue cannot be extended. The lockout bar can be secured with padlocks (see Figure 6)To pivo

35、t out, press the grooved part (only possible with bolt tongue retracted).Figure 6: Lockout bar secured with padlockEscape release (optional)The escape release is used to open a locked safety guard from the inside without tools.Warning!Loss of the safety function due to incorrect mounting of the esca

36、pe release.The actuation axis for the escape release must be inserted min. 10 mm into the handle module.In case of profile widths larger than 40 mm and on the usage of mounting plates use 50 mm actuation axis (order no. 106 761) and cut to length.In case of profile widths smaller than 40 mm, cut act

37、uation axis and protective sleeve to length.Align escape release axis at right angles to the handle module. See Figures 4 and 8. Install escape release so that operation as well as inspection and maintenance are possible.Important!The system enters into a latching fault when the escape release is ac

38、tuated. See system status table on page , state signal sequence erroneous (DIA1 flashes six times).Note!The system might not enter into a latching fault if the escape release is actuated very slowly.Key:1Padlock min. mm, max. 10 mmNote: You can fit a maximum of locks 8 mm.1Order No. 100464Order No.

39、111157System Manual Safety System MGB-AR in Combination with a Locking Module10Preparing the escape release1Fit door handle 2Insert actuation axis. The locking ring A must be in contact with the escape release B.3Tighten setscrew to Nm4Fit protective sleeveFigure 7: Preparing the escape release1324A

40、BProtective sleeveActuation axisExample with mounting plates:58,54D4(10)55,5(+4 mm per plate)250182Mounting platesD + 13,53,5(+4 mm per plate)D + 3System Manual Safety System MGB-AR in Combination with a Locking Module11InstallationWarning!Mounting must be performed only by authorized personnel.For

41、installation steps see Figure 8 and Figure 9 to 14.Install system so thatoperation of the mechanical release as well as inspection and maintenance are possible.Figure 8: Installation example for door hinged on the right (general view)4x M62x M60,5 Nm1 Nm (6x)Fastening material not included!Cut-out f

42、or escape releaseTightening torque 4 NmSystem Manual Safety System MGB-AR in Combination with a Locking Module1Changing Actuating Direction for Doors Hinged on the LeftImportant!It is only possible to make this change when the bolt tongue is not extended and an escape release is not yet mounted.As s

43、upplied, the handle module is set for doors hinged on the right.The safety guard opens by pressing down the door handle.The system is mounted the other way up for doors hinged on the left.The safety guard opens by pressing up the door handle (see Figure 9).For this reason the actuating direction of

44、the door handle must be changed (see Figure 9 - 14). CLOSEDOPEN132454Lift locking pin on the door handle using a screwdriver and hold in this position.5Turn door handle to right.1Push door handle upwards.2Unscrew locking pins to the marking3Push cover to the side.7a6b4 mm86Only on the usage of an es

45、cape release: Turn joint with hex screw counter-clockwise from position (a) to position (b).7Close cover.8Screw in locking pins and tighten to Nm.Figure 9: Changing actuating direction, step 1Figure 10: Changing actuating direction, step 2and 3Figure 11: Changing actuating direction, step 4and 5Figu

46、re 12: Changing actuating direction, step 6to 8System Manual Safety System MGB-AR in Combination with a Locking Module13 mm910OPENCLOSED9Undo setscrew.ATMove door handle 90 clockwise and fasten again.Tighten setscrew to NmAKState after the changeFig. 13: Changing actuating direction, step 9and ATFig

47、ure 14: Changing actuating direction, final stateProtection Against Environmental EffectsLasting and correct safety function requires that the system must be protected against foreign bodies such as swarf, sand, blasting shot, etc. which can become lodged in the locking and handle modules. For this

48、purpose a suitable installation position should be selected.Cover device during painting work!System Manual Safety System MGB-AR in Combination with a Locking Module14Electrical ConnectionWarning!In case of an error, loss of the safety function through incorrect connection.To ensure safety, both saf

49、ety outputs (OA and OB) must always be evaluated.The monitoring outputs O1 . O4 must not be used as safety outputs.Lay the connection cables with protection to prevent the risk of short cir-cuits.Caution!Risk of damage to equipment or malfunctions as a result of incorrect connec-tion.Do not use a control system with pulsing or switch off the pulsing function in your control system. The device generates its own clock signal on the output lines OA/OB. A downstream control system must tolerate these test p