1、,Safety Test安規測試,Test Item,Insulation Resistance TestInsulation Endurance TestLeakage Current TestInrush Current Test,Insulation Resistance Test,AimVerify insulation strength of products(驗證產品的絕緣強度)Spec Test point: (A+B)FGTest voltage: DC500VTest time:1minuteSystem condition: System power offCriteria
2、Insulation Resistance: 10meg ohm,Step,Insulation Endurance Test,AimInsulation Strength is tested using far higher than normal voltage to observe whether insulation is damaged or leakage current is too high.(以高於正常使用電壓的條件測試產品之絕緣強度,以觀察絕緣是否崩潰或洩漏電流是否過高,判定產品是否安全),Spec Test point : (A+B) FGTest voltage: AC
3、 1.5KV(130250) AC 1.0KV(Less than130V)Test time: 1 minuteSystem condition: System power off CriteriaLeakage Current: 10mA,Step,Leakage Current,Aim Under normal voltage,simulating when body contacts product,the current is checked whether to damage the safety of body. (在正常的工作電壓下,模擬人體接觸產品時流經人體之電流量以檢視該電
4、流量是否危害人身安全。) Spec*Test point: A FG, B FG, FGEarth,Palm RestEarth,*Input Resistance: 1.5Kohm*Input capacity: 0.15F*Input voltage: Standard voltage +10%Criteria:,Step,AC 220V,N/B之电源插座,AC Power Source,Inrush Current,Aim驗證產品在開關暫態之電流突破是否合乎產品規格 SpecTest voltage: 100V / 230VTest frequency: 50HZ / 60HZTrigger point: AC plug in Measure times: 5 times for eachCondition: System cold,Measure Item: Inrush current: 0 to peak Lasting time: The time from the start to x1.25 withstandard current value 其中x的确定为:从波形start到波形稳定时的緃坐标 之差 Criteria: Inrush Current: 52A Lasting Time: 500ms,