收藏 分享(赏)

灯具安规-IEC60598part2概述及新旧版差异.pdf

上传人:精品资料 文档编号:5025594 上传时间:2019-01-31 格式:PDF 页数:37 大小:357.73KB
下载 相关 举报
灯具安规-IEC60598part2概述及新旧版差异.pdf_第1页
第1页 / 共37页
灯具安规-IEC60598part2概述及新旧版差异.pdf_第2页
第2页 / 共37页
灯具安规-IEC60598part2概述及新旧版差异.pdf_第3页
第3页 / 共37页
灯具安规-IEC60598part2概述及新旧版差异.pdf_第4页
第4页 / 共37页
灯具安规-IEC60598part2概述及新旧版差异.pdf_第5页
第5页 / 共37页
点击查看更多>>
资源描述

1、葉志庭 燈具安規 -IEC 60598 part2 概述及新舊版差異 Outline IEC 60598-part 2簡介 IEC 60598-part2 新舊版差異 IEC 60598 Part 2: 簡介 -Overview -Abstract IEC 60598-2-1:1979 Luminaires. Part 2: Particular requirements. Section One: Fixed general purpose luminaires IEC 60598-2-2:2011 Luminaires - Part 2-2: Particular requirements

2、 - Recessed luminaires IEC 60598-2-3:2002+AMD1:2011 CSV Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting IEC 60598-2-4:1997 Luminaires - Part 2: Particular requirements - Section 4: Portable general purpose luminaires *紫色字為跟 LED較相關 Overview IEC 60598-2-5:2015

3、Luminaires - Part 2-5: Particular requirements Floodlights IEC 60598-2-7:1982 Luminaires. Part 2: Particular requirements. Section Seven: Portable luminaires for garden use IEC 60598-2-8:2013 Luminaires - Part 2-8: Particular requirements Handlamps IEC 60598-2-9:1987 Luminaires. Part 2: Particular r

4、equirements. Section Nine: Photo and film luminaires (non-professional) IEC 60598-2-10:2003 Luminaires - Part 2-10: Particular requirements - Portable luminaires for children IEC 60598-2-11:2013 Luminaires - Part 2-11: Particular requirements - Aquarium luminaires IEC 60598-2-12:2013 Luminaires - Pa

5、rt 2-12: Particular requirements - Mains socket-outlet mounted nightlights IEC 60598-2-13:2006+AMD1:2011 CSV Luminaires - Part 2-13: Particular requirements - Ground recessed luminaires IEC 60598-2-14:2009 Luminaires - Part 2-14: Particular requirements - Luminaires for cold cathode tubular discharg

6、e lamps (neon tubes) and similar equipment IEC 60598-2-17:1984+AMD1:1987+AMD2:1990 CSV IEC 60598-2-18:1993 Luminaires - Part 2: Particular requirements - Section 18: Luminaires for swimming pools and similar applications IEC 60598-2-19:1981 Luminaires. Part 2: Particular requirements. Section Ninete

7、en: Air-handling luminaires (safety requirements) IEC 60598-2-20:2014 Luminaires - Part 2-20: Particular requirements - Lighting chains IEC 60598-2-21:2014 Luminaires - Part 2-21: Particular requirements - Rope lights IEC 60598-2-22:2014 Luminaires - Part 2-22: Particular requirements - Luminaires f

8、or emergency lighting IEC 60598-2-23:1996+AMD1:2000 CSV Luminaires - Part 2-23: Particular requirements - Extra low voltage lighting systems for filament lamps IEC 60598-2-24:2013 Luminaires - Part 2-24: Particular requirements - Luminaires with limited surface temperatures IEC 60598-2-25:1994 Secti

9、on 25: Luminaires for use in clinical areas of hospitals and health care buildings Abstract IEC 60598-2-1:1979 Luminaires. Part 2: Particular requirements. Section One: Fixed general purpose luminaires Specifies requirements for fixed general purpose luminaires for use with tungsten filament, tubula

10、r fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V. IEC 60598-2-2:2011 Luminaires - Part 2-2: Particular requirements - Recessed luminaires IEC 60598-2-2:2011 specifies requirements for recessed luminaires incorporating electric light sources for operation from supply v

11、oltages up to 1 000 V. This section does not apply to air-handling or liquid-cooled luminaires. This third edition cancels and replaces the second edition published in 1996 and its Amendment 1 (1997), of which is constitutes a technical revision. The changes introduced by this new edition are those

12、required to maintain consistency later versions of IEC 60598-1 that have been published since the previous edition of this standard. IEC 60598-2-3:2002+AMD1:2011 CSV Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting IEC 60598-2-3:2002+A1:2011 specifies requirem

13、ents for: - luminaires for road, street lighting and other public outdoor lighting applications; - tunnel lighting; - column-integrated luminaires with a minimum total height above normal ground level of 2,5 m; - and for use with electrical lighting sources on supply voltages not exceeding 1 000 V.

14、This publication is to be read in conjunction with IEC 60598-1:2008. IEC 60598-2-4:1997 Luminaires - Part 2: Particular requirements - Section 4: Portable general purpose luminaires Specifies requirements for portable general purpose luminaires, other than handlamps, for use with tungsten filament,

15、tubular fluorescent and other discharge lamps on supply voltages not exceeding 250 V. IEC 60598-2-5:2015 Luminaires - Part 2-5: Particular requirements Floodlights IEC 60598-2-5:2015 specifies requirements for floodlights for use with electrical light sources on supply voltages not exceeding 1 000 V

16、. This third edition cancels and replaces the second edition published in 1998, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: it introduces requirements for the glass breaking test. IEC 60598-2-7:1982 Lum

17、inaires. Part 2: Particular requirements. Section Seven: Portable luminaires for garden use Specifies requirements for portable pedestal luminaires for use in places such as gardens and for portable luminaires for use in places such as flower beds, for use with tungsten filament, tubular fluorescent

18、 and other discharge lamps on supply voltages not exceeding 250 V. IEC 60598-2-8:2013 Luminaires - Part 2-8: Particular requirements Handlamps IEC 60598-2-8:2013 specifies requirements for handlamps and similar portable luminaires which are held in the hand, hooked up or resting on a surface for use

19、 with electric light sources on supply voltages not exceeding 250 V. This third edition cancels and replaces the second edition, published in 1996, its Amendment 1 (2000) and its Amendment 2 (2007). It constitutes a technical revision. This edition includes the following significant technical change

20、s with respect to the previous edition. IEC 60598-2-9:1987 Luminaires. Part 2: Particular requirements. Section Nine: Photo and film luminaires (non-professional) Specifies requirements for photo and film luminaires (non-professional) for use with low-pressure tungsten halogen lamps, specified in IE

21、C 60357. IEC 60598-2-10:2003 Luminaires - Part 2-10: Particular requirements - Portable luminaires for children Specifies requirements for portable child-appealing luminaires for use with tungsten filament lamps on supply voltages not exceeding 24 V (SELV). IEC 60598-2-11:2013 Luminaires - Part 2-11

22、: Particular requirements - Aquarium luminaires IEC 60598-2-11:2013 specifies requirements for household aquarium luminaires incorporating electric light sources on supply voltages not exceeding 1 000 V. This second edition cancels and replaces the first edition published in 2005. This edition const

23、itutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: IEC 60598-2-12:2013 Luminaires - Part 2-12: Particular requirements - Mains socket-outlet mounted nightlights IEC 60598-2-12:2013 specifies requirements for mains sock

24、et-outlet mounted nightlights for use with electric light sources, on supply voltages not exceeding 250 V a.c. 50/60 Hz. This second edition cancels and replaces the first edition published in 2006. It constitutes a technical revision for harmonization of thermal tests in 12.13 to relevant parts of

25、10.12.1 of IEC 60598-2-10. IEC 60598-2-13:2006+AMD1:2011 CSV Luminaires - Part 2-13: Particular requirements - Ground recessed luminaires IEC 60598-2-13:2006+A1:2011 specifies requirements for ground recessed luminaires incorporating electric light sources for operation from supply voltages up to 1

26、000 V, for indoor or outdoor use, e.g. in gardens, yards, carriageways, parking lots, cycleways, footways, pedestrian areas, swimming pools areas outside zones for SELV, nurseries and similar applications. IEC 60598-2-14:2009 Luminaires - Part 2-14: Particular requirements - Luminaires for cold cath

27、ode tubular discharge lamps (neon tubes) and similar equipment IEC 60598-2-14:2009 applies to luminaires for cold cathode tubular discharge lamps and similar equipment, operating on a no-load rated output voltage over 1 000 V but not exceeding 10 000 V, mainly used for general lighting, for indoor o

28、r outdoor applications and for supply voltages up to 1 000 V. This publication is intended to be read in conjunction with IEC 60598-1: Luminaires - Part 1: General requirements and tests. It was established on the basis of the seventh edition (2008) of that standard. IEC 60598-2-18:1993 Luminaires -

29、 Part 2: Particular requirements - Section 18: Luminaires for swimming pools and similar applications Specifies requirements for fixed luminaires intended for use in water, or in contact with water, for example in swimming pools, fountains, paddling pools, and garden pools, and for use with tungsten

30、 filament lamps. The contents of the corrigendum of March 2013 have been included in this copy. IEC 60598-2-19:1981 Luminaires. Part 2: Particular requirements. Section Nineteen: Air-handling luminaires (safety requirements) Specifies safety requirements for air-handling luminaires for use with a ve

31、ntilation space (plenum), for use with tubular fluorescent lamps on supply voltages not exceeding 1000 V. IEC 60598-2-20:2014 Luminaires - Part 2-20: Particular requirements - Lighting chains IEC 60598-2-20:2014 specifies requirements for lighting chains fitted with series, parallel or a combination

32、 of series/parallel connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V. For combinations where rope lights (also known as sealed lighting chains) are included, see IEC 60598-2-21. This fourth edition cancels and replaces the third edition (2010). This e

33、dition includes the following significant technical changes with respect to the previous edition, where the requirements for rope lights (sealed lighting chains) have been removed and are now dealt with in IEC 60598-2-21. IEC 60598-2-21:2014 Luminaires - Part 2-21: Particular requirements - Rope lig

34、hts IEC 60598-2-21:2014 specifies requirements for rope lights (sealed lighting chains) fitted with non-replaceable series- or parallel- or a combination of series/parallel-connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V. IEC 60598-2-22:2014 Luminair

35、es - Part 2-22: Particular requirements - Luminaires for emergency lighting IEC 60598-2-22:2014 specifies requirements for emergency luminaires for use with electrical lamps on emergency power supplies not exceeding 1 000 V. This fourth edition cancels and replaces the third edition published in 199

36、7, AMD1:2002 and AMD2:2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition IEC 60598-2-23:1996+AMD1:2000 CSV Luminaires - Part 2-23: Particular requirements - Extra low voltage lighting systems for

37、 filament lamps Specifies requirements for extra low voltage systems for filament lamps intended for ordinary use on supply voltages not exceeding 1 000 V. The luminaires, being connected in parallel, are supplied via freely suspended continuous supporting conductors or profiles. The current in the

38、output circuit of the system is limited to 25 A. This consolidated version consists of the first edition (1996) and its amendment 1 (2000). Therefore, no need to order amendment in addition to this publication. IEC 60598-2-24:2013 Luminaires - Part 2-24: Particular requirements - Luminaires with lim

39、ited surface temperatures IEC 60598-2-24:2013 series specifies requirements for luminaires intended for use where the necessity of limited temperature on the outer surface exists, due to the risk of thermal effects, combustion or degradation of materials but where the risk of explosion in the atmosp

40、here does not exist. IEC 60598-2-25:1994 Luminaires - Part 2: Particular requirements - Section 25: Luminaires for use in clinical areas of hospitals and health care buildings Details specific requirements for luminaires for use with tungsten filament, fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V for use in clinical areas in which medical treatment, examination and medical care takes place in hospital and health care buildings. The contents of the corrigendum of September 1994 have been included in this copy.

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 企业管理 > 经营企划

本站链接:文库   一言   我酷   合作


客服QQ:2549714901微博号:道客多多官方知乎号:道客多多

经营许可证编号: 粤ICP备2021046453号世界地图

道客多多©版权所有2020-2025营业执照举报