1、Gen2曳引钢带的清洁指引维修发布 2008.12.16Field instruction on Gen2 belt cleaning Service issue 2008.12.16第一部分Section 1背景: 在安装和维修的一些工地曾经出现过钢带噪音问题,通过使用了VP-420535-GBW 调整剂,问题可以得到解决。最近,OTIS总部通过和国外的沟通,了解到关于此调整剂的最新信息:1. 该调整剂并没有正式的投入使用。分公司使用该调整剂是有严格限制的,必须得到维修总部的特别批准才能使用。2. 此调整剂会降低曳引力。 3. 目前上海配件中心已召回此种调整剂。Background: Som
2、e jobsites of Installation and service have suffered CSB noise problems, later those noise problems were solved by using the VP-420535-GBW conditioner. Recently, OTIS OCL communicated with oversea department, got some new important messages on this conditioner as follow: 1, This conditioner hasnt be
3、en formally released to the jobsite. Branch is strictly restricted to use the conditioner and must get HQ SVCs special approval. 2, The conditioner may compromise traction force. 3, At present, SPC has recalled this conditioner.第二部分Section 2清洁剂的区分: 请注意区分VP-420535 和VP-420535- GBW 这两种清洗剂。VP-420535 清洗剂
4、仅用于清洗钢带,且会从钢带表面清除蜡状物。如钢带有轻微的打滑,必需要使用这种清洁剂。VP-420535-GBW 被称为 钢带的调整剂 ,它被开发用来消除钢带引起的噪音。它会将少量的蜡状物涂到钢带表面来解决钢带的噪音问题。Cleaner Distinguish: Please carefully distinguish the VP-420535 cleaner and VP-420535-GBW conditioner.VP-420535 is only for cleaning belts, and has the affect of removing wax from the belt s
5、urface. This cleaner is needed if there is slight belt slipping.VP-420535-GBW is known as Belt Conditioner. It was developed to eliminate noise caused by the belts. It does this by applying a small amount of wax to the belt surface to solve the belt noise problem.第三部分Section 3使用VP-420535- GBW 的安全预警:
6、 由于使用此种钢带调整剂会降低曳引力,因此未经允许,现场人员不得使用VP-420535-GBW 。大部分调整剂已经被SPC召回,如果分公司仍然存有少量调整剂,请务必与SPC联系并寄回。Usage VP-420535-GBW Safety Warning: Field people cant use the VP-420535-GBW conditioner without authorization because this conditioner may compromise traction force.Possible a large amount of conditioners alr
7、eady recalled by SPC, if branch still has a few conditioners, have to contact SPC and ship return.第四部分Section 4VP-420535-GBW 的使用申请和数据记录: 如果分公司必须申请使用钢带调整剂来解决钢带的噪音,1 现场须确定电梯的载重=1600kg的电梯禁止使用调整剂。2 现场必须检查钢带的张力,校准度和轮的轴承,确保所有的机械情况都是好的。3 使用ST工具在软件中确定电梯的钢带没有打滑情况。MCS220控制柜,使用 TT的MCB-2-B菜单Rope Slip来检测钢带是否打滑。M
8、CS321控制柜,使用 TT的Event Log菜单来检查是否有代码2100或2101的打滑故障记录。4 确认1-3项后,使用PMT或者录音设备记录电梯运行时的噪音录音,提供给总部维修部FOD来申请使用调整剂。5 维修总部FOD确认可以使用调整剂后,将同意SPC向现场提供。6 现场为电梯使用调整剂后,必须重复第3项工作,确认电梯的钢带没有打滑情况,否则需及时通知维修总部FOD 来采取相应的措施。7 最后,现场必须记录相关数据反馈给总部维修部FOD存档。包括使用钢带调整剂的时间、次数,电梯的整机号、梯型、梯龄、载重、层站、运行次数。VP-420535-GBW Using Apply and Da
9、ta Log: When branch have to apply belt conditioner to solve belts noise problem,1 Field need to make sure unit load =1600kg unit is forbidden use conditioner.2 Field need to check belts tension, alignment and sheave bearings, make sure all mechanical issue is Ok.3 Using Service Tool access microproc
10、essor, make sure belts hasnt slip issue.MCS220 control system, use TT MCB-2-B of Rope Slip menu, detect belt is slip or not.MCS321 control system, use TT Event Log menu, check has code 2100 or 2101 slippage log or not.4 When get items 1-3 confirmed, field need to take a PMT reading or other sound re
11、cording for a running noise record, to apply to OCL Service FOD to use the conditioner.5 If Service FOD affirms field can use the conditioner, will approve SPC provide it to field.6 Once field use conditioner to specified unit, need repeat item 3 job, to make sure belts hasnt slip issue. If not, fie
12、ld need to inform Service FOD for get corresponding solving advice.7 At last, field must record relational data, keep and feedback to OCL Service FOD saving. Include using belt condition date, times, units machine No, model type, ages, load, landing, running times.Conditioner record 记 录 表第五部分Section
13、 5VP-420535清洁剂的使用说明:一般来说,Optimus 系统使用的 CSBs(曳引带)不需要定期清洁。只有当曳引带上附着有大量的建筑灰尘或液态污垢时,才需要清洁。并且必须遵守以下原则: - 如果曳引带不脏,则不必清洁或擦抹。- 如果曳引带附着有干燥的污垢(灰尘) ,则使用清洁的干布擦净。- 如果曳引带需要清洁,则只能使用 VP-420535 (#2) 清洁剂清洁。VP-420535 Cleaner instruction:In general the CSBs utilized on the Optimus system do not require periodic cleanin
14、g. Only if a significant amount of construction debris or a fluid contaminant appears on the belts will cleaning be required. The following considerations must be adhered to - If the belt is not dirty leave it alone, do not clean the belt or wipe it down- If it is a dry contaminant (dust) wipe the b
15、elt with a clean dry cloth.- If the belts need to be cleaned, clean with VP-420535 cleaner # 2 only. 第六部分Section 6VP-420535-GBW 钢带调整剂的使用步骤,为清除钢带噪音:VP-420535-GBW Belt Conditioner Application Steps for Belt Noise Removal:通则所有工地工作都必须完全遵守OTIS全球工地安全标准(WWJSSS)及当地的安全标准。执行该程序时,应特别考虑电梯的控制,LOTO上锁及标记,电气安全并使用适当
16、的PPE( 手套等) ,必须完成JHA工作风险评估。若不确定工作任务是否符合工地安全标准,要立即停止工作并与主管进行沟通协商。GENERALAll jobsite work activity must be in full compliance with OTIS Worldwide Jobsite Safety Standards (WWJSSS) and local safety rules. When carrying out this procedure, particular consideration should be given to control of the elevat
17、or, LOTO, electrical safety and using appropriate PPE (hand gloves, etc.). Complete a Job Hazard Analysis (JHA). If you are unsure about the work task at hand, immediately stop work and consult with your supervisor.步骤Step任务Task注释Comments1. 控制电梯并检修开到顶层Capture car and remove from service2. 在顶层进入轿顶Acce
18、ss car top at top landing 控制柜打上检修开关Place controller on CRI3.使用轿顶检修向下开电梯到最底层楼上面的一层Using TOCI travel down hoistway to thefloor above the bottom floor4.测试并验证最底层上面这一层楼的门锁触点,当门打开时电梯必须停下来Test and verify that the door lock contact on the floor above the bottom landing will stop the car when opened如果在后面的工作中
19、需要从其他楼层退出轿顶时,必须重新验证轿顶进入程序Needed later to egress car top at landing other than original car top access landing5. 把电梯开到井道最高的位置Move car top to the highest point in hoistway 按下轿顶急停开关Apply car top stop switch6.打轿顶检修开关操作,电梯停下后,在轿顶进行涂抹钢带调整剂的工作Work from the car top to apply belt conditioner while on TOCI使用轿
20、顶检修开关 在触碰钢带或涂抹钢带调整剂以前打开轿顶急停开关 Use TOCI Disable car top stop button before touching belts or applying belt conditioner7.多倒一些钢带调整剂到清洁的抹布上直到抹布潮湿,但是不会让调整剂从抹布上滴下Pour a generous amount of belt conditioner on a clean rag to wet the rag, but not enough to have it dripping from rag使用沾有钢带调整剂的潮湿的抹布擦钢带Wipe belt
21、s with rag moistened with belt conditioner8.开始向钢带上涂抹钢带调整剂,当电梯在井道中的每层顶端位置时Start applying belt conditioner to the belts with the car at the very top of hoistway. 钢带调整剂一直涂抹到在轿顶反绳轮的上部分钢带即可。所有钢带的所有边缘都要涂抹。在钢带的 4 面上同时擦钢带调整剂。Apply belt conditioner to the belts just above car top sheave. Apply to all sides o
22、f all belts. Wipe belt conditioner on about 4 feet of belt at a time. 9.在沿着井道向下的途中,重复涂抹钢带调整剂到钢带4面上的工作。Repeat the application of belt conditioner to four foot sections of belt as you work your way down the hoistway. 一旦钢带调整剂已经被涂过,不要向上运行电梯。Do not run the car up once belt conditioner has been applied.10
23、.当到达曾经验证过安全出口的那个最底层的时候,退出轿顶。不要运行电梯了,因为刚刚涂抹过钢带调整剂。Exit the car top when you reach the lowest landing where you can safely egress the car top without running up and on to freshly applied belt conditioner在测试并验证过门锁的楼层退出。正常情况下是最底层上面的那一层。保持对电梯的控制。Floor at which door lock was tested and verified. Normally
24、floor above bottom landing.Keep control of the elevator11.把轿顶打到正常运行的位置Place Top of car station to the Normal runposition电梯控制柜仍然在检修模式Elevator controller will still be on CRImode12. 隔一段时间回到控制间Enter control room/space13.使用控制柜里的SPB板,按上 DDO和CHCS开关Using Service Panel Board in controller, enable DDO and CH
25、CS. 当按钮确实激活的时候,它们的指示灯会常亮LEDs will illuminate above buttons when activated14.使用 SPB 板上的 CCTL 顶层呼叫和 CCBL 底层呼叫按钮,运行电梯到顶层,运行电梯到底层Run the car to the top and to the bottom of the hoistway using the Service Panel Boards CCTL top and CCBL bottom floor call buttons运行电梯 20 分钟,使钢带调整剂完全涂抹到所有钢带的每一个位置。Run car for
26、 about 20 minutes to fully transfer belt conditioner to the entire length of all belts. 15.在控制柜观测,电梯的性能和再平层情况Observe controller for releveling and elevator performance16.如果结果是有效的可以执行下一步(如果没有效果,在顶层和底层间往返运行电梯,让钢带调整剂进一步干下来)Move on to next step if results are positive (If not positive, run top to bottom
27、 to further dry the belt conditioner)17.继续控制电梯,并且在井道内不断运行电梯多停靠在一些楼层,听钢带的噪音,校验电梯的性能Maintain control of elevator and run the car through the hoistway stopping at numerous floors and listen for any belt noise and verify performance. 钢带应该安静的运行,且电梯应该在启动和停车时没有再平层问题。Belts should run quiet and elevator shou
28、ld have controlled stops and starts without releveling18. 如果结果是有效的可以执行下一步Move on to next step if results are positive19.从控制柜的运行计数器,记录电梯启动的次数,并记录涂抹钢带调整剂的日期和运行次数Record number of starts from controller run counter and record both the date and number of runs when belt conditioner was applied.20.使用服务器清除所有故障记录,并把电梯恢复到工作状态Clear all fault logs using service tool and place elevator back in service