1、USERS MANUALHORIZONTAL DIGITAL SCALE UNITS MAINTAINANCE INSTRUCTIONi. Before using the digital scale unit for the first time, wipe the protective film with a soft dry cloth (or soaked with cleaning oil). Keep the protective film free from liquid material.ii. Never apply any electric pressure on any
2、part of the caliper for fear of damaging its chip. NOMENCLATURES1. Cover Clamp 5. Data Output Cover2. Protective Sticker 6. OFF/ON Button3. LCD Display 7. Zero Setting Button4. inch/mm Switch Button 8. Battery Cover KEYS FUNCTIONSi. OFF/ON ButtonPress this button to turn on power; Press it long to t
3、urn off power. ii. mm/inch ButtonPress this button to select measuring systems, Metric or English.iii. Zero Setting ButtonPress this button to do Zero setting at any position. TECHNICAL SPECIFICATIONi. Resolution (mm) :0.01mmii. Power:One 1.55v button celliii. Measuring Speed:1.5m/siv. Working Condi
4、tions:Temperature 0+40 ,Humidity80%. v. Storage Temperature:0+60 POSSIBLE MALFUNCTIONS AND SOLUTIONSTrouble Possible cause SolutionDigit flashes Low voltage Replace the button cellLow voltage Replace the button cellNo displayPoor contact Adjust and clean the battery seatFixed digits Accidental trouble in circuit Take out the battery and put it back after one minute