收藏 分享(赏)

电子围栏说明书英文版.doc

上传人:eukav 文档编号:4454247 上传时间:2018-12-29 格式:DOC 页数:16 大小:1.68MB
下载 相关 举报
电子围栏说明书英文版.doc_第1页
第1页 / 共16页
电子围栏说明书英文版.doc_第2页
第2页 / 共16页
电子围栏说明书英文版.doc_第3页
第3页 / 共16页
电子围栏说明书英文版.doc_第4页
第4页 / 共16页
电子围栏说明书英文版.doc_第5页
第5页 / 共16页
点击查看更多>>
资源描述

1、1Directorypreface. 2safe note 3一.function and feature. 41.1 function 41.2 feature 4二、instruction. 52.1 design basis 52.2. characteristic . 52.3 technical index 52.4 LEDindicated 52.5 The front ,bottom of controller 62.6 wire connection instruction. 6三、design requirement. 63.1safety level . 63.2 secu

2、rity. 7四、installation . 74.1 install mode. 74.2 install angle. 94.3 terminal rod/insulator install. 94.4 middle rod/insulator install.104.5middle pull rod/insulator install.104.6 tensioner install.104.7lightning-arrester .104.8alloy wire connection.114.9grounding114.10 ground wiring.11五、controller i

3、nstall &connection.115.1 controller install.115.2 controller and fence connection12六、debug and alarm test126.1 electrify check126.2alarm test. .12七、install rule & security note.158.1 install rule158.2 safety note and some removing methods 16Preface shanghai Yi Section Company is specialized in manuf

4、acturing electric security fence with its own R&D department factory located in Shenzhen. Yi Section company persistently follows the principle“do everything with whole 2hearted“, through superior quality and zealous service, Yi Section tries every efforts to respond the users that gives us long-ter

5、m support and trust. Pulse electric fence energizer and perimeter accessory that Yi Section products and develops conforming to the requirements of GB/T7946-2008 pulse electric fence installation and safe operation and meet CEI-61011 international electric fence standard. The patent water proof casi

6、ng design, professional output method, advanced difference voltage output technology, unique LCD display function, make the products as the leader in the industry. The products sell to Unite States, Europe, Australia, Africa, and Asian country , Yi Section will be the base of international productio

7、n and service. The products are widely used in ware house, industry areas, power station, private house, villa, school, car parks, plant areas, airpot, prison, military base.etc.Security note:Unless high/low voltage output disarmed of electric fence, dont touch the conductor part of the system. Dont

8、 install electric fence during the thunder, don t install controller in moist place.Before install and use the product, do the safe educational technology training work.During the installation, in order to use normally in future, follow the instructions to make sure the grounding of products. Refer

9、to “4.9 item” When the product is electrified , the inside of controller is 220v 50Hz AC current, 5-10KV high voltage pulse on the output port and electric fence, dont touch it to make sure security.The user must know the related electric device knowledge, and read the user instruction and operate i

10、t carefully before install it with correct use methods, otherwise , our side dont bear any responsibility if any accident arise.Once abnormal case happen, should make sure the power off, then professional staffs check and analysis repair or contact our company, dont repack it by your own.3一Function

11、and feature There are two kinds of existing security products. One kind is a fence, like traditional brick wall, cement wall, glass wall, iron fence and so on, has the obvious contours, encircles the defense area, has the impediment external invasion function, but does not have the alarm and the sur

12、veillance function. Another kind is the alarm system, like the infrared correlation alarm apparatus, divulge electric cable, CCTV and so on, they have the alarm or the surveillance function, but does not have the impediment function. The smart pulse electric fence system integrate the prevents and a

13、larm functions together, and increase the high voltage deterrent effect, not only have visible fence, but also have smart multi-zone controller, the alarm system becomes brand new perimeter security system.1.1 system function1.1.1 have complete and explicit dividing line fence,and formidable impedim

14、ent and deter function.1.1.2 have low rate of false alarm function,when the outer fence alarm,the display windows rapidly display which zone suffers break,short-circuit and tamper, reflect the current condition. 1.1.3 The DC 12V alarm connection,dry contact signal output, can linkage with other secu

15、rity system, improve the systems safe rank. 1.1.4 distinction function of electric fence and can detect all kinds of invasion rank, can differentiate the accidental invade from forceful invade ability. The accidental intruder see the alarm or suffer from the electric shock, the leave, the alarm appa

16、ratus do not send out alarm. The intruder invade forcefully , so that the electric fence will be destroyed, in this case, the system will send out alarm. Only the intruder really invade and destroy the system, then will send alarm, will not alarm mistakenly and fails to alarm.1.2 system feature 1.2.

17、1 Absolute safety and alarm perceive The traditional high voltage pulse electric net system doesnt have alarm perceive function, only through high voltage, strong current to impediment intruder. It is very easy to get intruder disable, even dies and so serious results. The smart pulse electric fence

18、 system adopts low energy pulse high voltage((5 10KV),because the energy is extremely low,the response time is extremely short, will not cause the damage to the humanbody. Once touched, will just leave dut to electric shock. 41.2.2 The low rate of false alarm and strong Adaptability The smart pulse

19、electric fence system is not affected by environment (for example. trees, animals, shake.etc ) and climate ( wind, snow, rain and fog,etc) and not limited by terrain height and winding degree. The rate of false alarm is very low.1.2.3 impediment and alarm dual function The new concept of smart pulse

20、 electric fence system is to prevent the intruder out of from the fence area,without the crime is the goal, give the intruder one kind of deterrent feeling and impediment function, dare not act rashly, achieve the security, reduces the crime.1.2.4 continuous work,set armed/disarmed .1.2.5 use the 12

21、V/4Ah battery as backup power supply,when the power supply is off,can work continually. 1.2.6 According to users request and site geographical environment, carry out the design and installation, and work with multiple modern security products, such as CCTV monitored system, television supervisory sy

22、stem and GSM system to improve the system security ranks.1.2.7 Absolute safety, conforms to the international CE certification and is also in conformity with IEC 60335-2-76 and the GB/T7946-2008 request, and get approved from public security form test.二、product instructions 2.1 product design basis:

23、 GB/T7946-2008 “Pulse electric fence installation And Safe operation“2.2 product characteristic: difference voltage output technology: every wire has voltage, have the differential voltage between the two adjacent wires. LCD display the monitor state indicating the voltage on every wire. high/low vo

24、ltage switch manually, long-distance equipment auto switch function. short circuit, break and tamper alarm, equipment fault auto-detect. waterproof casing and downward appearance design guiding the industry development. RS 485 main line control, keypad, computer, network and multiple long distance m

25、anagement solution.5 DC12V, open/close dry contact alarm output, can work with other modern security products. 2.3 product technical index 2.3.1 power supply: AC180V-240v 50Hz 2.3.2 use environment2.3.2.1 Temperature :-40-+502.3.2.2 moisture: :95%2.3.3 output index: Output peak voltage: 5KV10KVOutpu

26、t low voltage: 7001000V Peak current of pulse: 10A Pulse duration: 0.1sPulse interval time: 1sMax quantity of electricity of pulse: 2.5mCMax energy of pulse: 5.0JSystem power consumption: 10w 2.4 LED indicated lamp condition instructions:2.4.1 AC 220V or DC12V,when power supply input ,the green indi

27、cated lamp is bright. 2.4.2 when armed,the yellow indicated lamp is bright. When disarmed,it shows off. 2.4.3 when alarm break,the red indicated lamp is bright.2.4.4 when alarm short circuit,the red indicated lamp is bright2.4.5 when open cover, the red indicated lamp of tamper is bright.62.5 the fr

28、ont and bottom of controller instructions.2.6 the wire connection of controller instruction( above drawing)2.6.1 the controller comprise two parts: input and output,the positive pulse from output part”1st line high voltage output port” transfer to fence wire, then return back to the receiver part “

29、1st line high voltage input port”, negative pulse from output”2nd line high voltage output port” transfer to fence wire, then return back to the receiver part” 2nd line high voltage input port” ,so form positive and negative pulse closed circuit on the front fence.2.6.2 high voltage earth output: ca

30、n share the same earth output with lightning arrester, strong/weak earth separate. 2.6.3 voltage switch: use for switching high/low voltage mode or automatic working mode.2.6.4 keypad output: can connect keypad directly or RS485 transfer RS 232,then connect to computer by long distance control, The

31、RS 485 connection of each controller needs to go hands by hands connection, multiple connection is not allowed.2.6.5 switch output: output open/close dry contact signal, needs to connect with other linkage device.2.6.6 alarm output: when alarm, output DC 12V voltage, connect with alarm device DC 12v

32、 below 10W.2.6.7 power switch: control the energizer on/off.2.6.8 power supply input: connect AC 220V power source.7三、design request of electric fence 3.1 according to different security rank, configurate suitable electric fence,usually divide into 、III the three rank. general security rank, uses 4

33、lines system, the monitor zone partition does not surpass 500 meters. medium security rank, uses 8 lines system, the monitor zone partition does not surpass 250 meters.III higher security rank, uses 12 lines system, the monitor zone partition does not surpass 100 meters.Every zone must configurate i

34、ndependent controller, and have different triggered alarm apparatus, can indicate the alarm zone number. The alarm output usually linkage with CCTV, red-infrared correlation, spotlight, alarm apparatus etc. When applied, the length of monitor zone should set according to the perimeter total length,

35、the terrain and the objective site environment. 3.2 Security 3.2.1 dont allow get the AC power supply on electric fence. when the product gets faulty, please make sure the electric fence without any AC power supply.3.2.2 product used the rectification voltage dropping DC 12V, then voltage-rise to co

36、ndenser charge, finally electric capacity pulse discharge boosting transformer, the output energy is limited by rectification, primary voltage-rise, electric capacitance discharge, so many links, without harm to human body and absolute safety.3.2.3 association factor and the influence of electric sh

37、ock:The electric pulse will not injure the intruder, to avoid the associated responsibility, firstly, electric fence warning signs should hang up at every other 10 meters striking position noted” electric fence, forbid climbing”, secondly, the height of electric fence should be above 1.8meters, if t

38、he height of electric fence is not high, should install isolated netting or wall to avoid accident.3.2.4 electric fence should not be with other power circuit and telecommunication wires on the same pole.3.2.5 electric fence should keep a certain safe distance from the power circuit. The minimum dis

39、tance as shown in the table 3-1 Electric cable voltage rank horizontal distance with electric fence vertical distance with electric fence 10KV below 2.5m 2m35110KV 5m 3m220KV 7m 4m330KV 9m 5m500KV 9m 5m3.2.6 horizontal distance between electric fence and public rod border should be above 5m( except

40、the electric fence on top of the wall)3.2.7 electric fence has pulse high voltage, when bad connection or close to charged conductor, will have fire spark. 8Thus, electric fence should install without any flammable gas, and without any flammable fluid place. According to the related national standar

41、d, keep enough safe distance, or take the safe measures to isolate.3.2.8 When inspect the place to install electric fence, pls make sure the electric fence without any conflict with the electric wire, pipeline from the ground. And without any sundry goods at nearby place, whether the electric fence

42、is influenced strongly by transmitting station and other high frequency device. If have, must mark the signal wire with STP shielded twisted pair at the construction drawing. 四、 Electric fence install 4.1 install mode: 4.1.1 install on top of the wall.Install the electric fence on top of wall, the h

43、eight of fence wall should be above 1.8meters, the wire pole/rod may have welding ,clip or buried the three modes, should choose suitable mode according to the fence structure condition.For example, install at the steel fence, can take the welding, install at the concrete wall, can take buried mode

44、to make sure stable, artistic, may use other modes also. 4.1.2 The attached install The installation attaches on the fence or top or inside, the fence wall directly withstanding the pressure and wire tension, before installation, pls make sure the structural strength of the wall, if unreliable, shou

45、ld reinforce in advance.The metallic conductor wire from the front end of electric fence spacing to the wall should be smaller than 700mm. 94.1.3 stand alone electric fenceInstall the electric fence around the building, because the height is above 1800mm, the wire number reaches 8-20, the strength o

46、f the wire to the terminal rod/pull rod tensity must be big, hence, terminal rod/ pull rod must have enough strength, and the embedment must be stable. If the soil is solid, may directly bury the wire of terminal rod and pull rod ends to underground 60cm to do fixed. If the rigidity of terminal wiri

47、ng rod is insufficient, should increase the support rod. Although the middle pull rod does not withstand the tensity of wire, but must support the pressure of multiple wires. Therefore, also needs to install it stably.May take buried mode installation. Follow the chart 12 wires stand alone installat

48、ion.4.2 electric fence installation angle: ( the angle with wall) see the right drawing.4.2.1 according to the site condition and the first party request((0 、22.5 、45、67.5、90、112.5、135 、157.5、180)and the inclined direction( inclination angle, camber angle, vertical or horizontal ) installation. 4.2.

49、2 according to the perimeter condition: if resident area, school nearby, suggested by inclination angle or vertical installation, spacious area suggested to install by camber angle, if the height of wall is above 2.5meters, take horizontal installation.4.2.3 According to the protection object: if prevent from outside invasion, suggest camber angle installation, if prevent from interior climbing, suggest inclination angle installation. 4.3 terminal rod/terminal rod insulator installation Fix the terminal rod insulator on the terminal ro