1、 Model 2700 Multimeter/Switch SystemUsers Manual吉时利数据采集器操作使用手册美国吉时利华南营销平台深圳市金博宇科技有限公司传真:手机:1.888.KEITHLEY (U.S. only)地址:深圳市宝安区民治街道梅陇路梅陇公馆室A G R E A T E R M E A S U R E O F C O N F I D E N C EWARRANTYKeithley Instruments, Inc. warrants this product to be free from defects in material and workmanship

2、for aperiod of 3 years from date of shipment.Keithley Instruments, Inc. warrants the following items for 90 days from the date of shipment: probes, cables,rechargeable batteries, diskettes, and documentation.During the warranty period, we will, at our option, either repair or replace any product tha

3、t proves to be defective.To exercise this warranty, write or call your local Keithley representative, or contact Keithley headquarters inCleveland, Ohio. You will be given prompt assistance and return instructions. Send the product, transportationprepaid, to the indicated service facility. Repairs w

4、ill be made and the product returned, transportation prepaid.Repaired or replaced products are warranted for the balance of the original warranty period, or at least 90 days.LIMITATION OF WARRANTYThis warranty does not apply to defects resulting from product modication without Keithleys express writ

5、tenconsent, or misuse of any product or part. This warranty also does not apply to fuses, software, non-rechargeablebatteries, damage from battery leakage, or problems arising from normal wear or failure to follow instructions.THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, I

6、NCLUDINGANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. THEREMEDIES PROVIDED HEREIN ARE BUYERS SOLE AND EXCLUSIVE REMEDIES.NEITHER KEITHLEY INSTRUMENTS, INC. NOR ANY OF ITS EMPLOYEES SHALL BE LIABLE FORANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISIN

7、G OUTOF THE USE OF ITS INSTRUMENTS AND SOFTWARE EVEN IF KEITHLEY INSTRUMENTS, INC., HASBEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. SUCH EXCLUDED DAM-AGES SHALL INCLUDE, BUT ARE NOT LIMITED TO: COSTS OF REMOVAL AND INSTALLATION,LOSSES SUSTAINED AS THE RESULT OF INJURY TO ANY PERSON, O

8、R DAMAGE TO PROPERTY.Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 440-248-0400 Fax: 440-248-61681-888-KEITHLEY (534-8453) Sales Ofces: BELGIUM:CHINA:FINLAND:FRANCE:GERMANY:Bergensesteenweg 709 B-1600 Sint-Pieters-Leeuw 02-363 00 40 Fax: 02/363 00 64Yuan Chen Xin Building, Room

9、705 12Yumin Road, Dewai, Madian Beijing 100029 8610-6202-2886 Fax: 8610-6202-2892Tietjntie 2 02130 Espoo Phone: 09-54 75 08 10 Fax: 09-25 10 51 003, alle des Garays 91127 Palaiseau Cdex 01-64 53 20 20 Fax: 01-60 11 77 26Landsberger Strasse 65 82110 Germering 089/84 93 07-40 Fax: 089/84 93 07-34GREAT

10、 BRITAIN: Unit 2 Commerce Park, Brunel Road Theale Berkshire RG7 4AB 0118 929 7500 Fax: 0118 929 7519INDIA:ITALY:Flat 2B, Willocrissa 14, Rest House Crescent Bangalore 560 001 91-80-509-1320/21 Fax: 91-80-509-1322Viale San Gimignano, 38 20146 Milano 02-48 39 16 01 Fax: 02-48 30 22 74KOREA: FL., URI

11、Building 2-14Yangjae-Dong Seocho-Gu, Seoul 137-130 82-2-574-7778 Fax: 82-2-574-7838Postbus 559 4200 AN Gorinchem 0183-635333 Fax: 0183-630821c/o Regus Business Centre Frosundaviks All 15, 4tr 169 70 Solna 08-509 04 679 Fax: 08-655 26 10Kriesbachstrasse 4 8600 Dbendorf 01-821 94 44 Fax: 01-820 30 81N

12、ETHERLANDS:SWEDEN:SWITZERLAND:TAIWAN: 1FL., 85 Po Ai Street Hsinchu, Taiwan, R.O.C. 886-3-572-9077 Fax: 886-3-572-9031 Copyright 2001 Keithley Instruments, Inc.Printed in the U.S.A.11/01Model 2700 Multimeter/Switch SystemUsers Manual2001, Keithley Instruments, Inc.All rights reserved.Cleveland, Ohio

13、, U.S.A.Fifth Printing, November 2001Document Number: 2700-900-01 Rev. EManual Print HistoryThe print history shown below lists the printing dates of all Revisions and Addenda createdfor this manual. The Revision Level letter increases alphabetically as the manual undergoes sub-sequent updates. Adde

14、nda, which are released between Revisions, contain important change in-formation that the user should incorporate immediately into the manual.Addenda are numberedsequentially. When a new Revision is created, allAddenda associated with the previous Revisionof the manual are incorporated into the new

15、Revision of the manual. Each new Revision includesa revised copy of this print history page.Revision A (Document Number 2700-900-01) November 1999Revision B (Document Number 2700-900-01) February 2000Revision C (Document Number 2700-900-01) November 2000Revision D (Document Number 2700-900-01)July 2

16、001Revision E (Document Number 2700-900-01) November 2001All Keithley product names are trademarks or registered trademarks of Keithley Instruments, Inc.Other brand names are trademarks or registered trademarks of their respective holders.Safety PrecautionsThe following safety precautions should be

17、observed before using this product and any associated instrumentation. Althoughsome instruments and accessories would normally be used with non-hazardous voltages, there are situations where hazardousconditions may be present.This product is intended for use by qualied personnel who recognize shock

18、hazards and are familiar with the safety precautionsrequired to avoid possible injury. Read and follow all installation, operation, and maintenance information carefully before us-ing the product. Refer to the manual for complete product specications.If the product is used in a manner not specied, t

19、he protection provided by the product may be impaired.The types of product users are:Responsible body is the individual or group responsible for the use and maintenance of equipment, for ensuring that the equip-ment is operated within its specications and operating limits, and for ensuring that oper

20、ators are adequately trained.Operators use the product for its intended function. They must be trained in electrical safety procedures and proper use of theinstrument. They must be protected from electric shock and contact with hazardous live circuits.Maintenance personnel perform routine procedures

21、 on the product to keep it operating properly, for example, setting the linevoltage or replacing consumable materials. Maintenance procedures are described in the manual. The procedures explicitly stateif the operator may perform them. Otherwise, they should be performed only by service personnel.Se

22、rvice personnel are trained to work on live circuits, and perform safe installations and repairs of products. Only properlytrained service personnel may perform installation and service procedures.Keithley products are designed for use with electrical signals that are rated Installation Category I a

23、nd Installation Category II,as described in the International Electrotechnical Commission (IEC) Standard IEC 60664. Most measurement, control, and dataI/O signals are Installation Category I and must not be directly connected to mains voltage or to voltage sources with high tran-sient over-voltages.

24、 Installation Category II connections require protection for high transient over-voltages often associated withlocalAC mains connections.Assume all measurement, control, and data I/O connections are for connection to Category I sourc-es unless otherwise marked or described in the Manual.Exercise ext

25、reme caution when a shock hazard is present. Lethal voltage may be present on cable connector jacks or test xtures.The American National Standards Institute (ANSI) states that a shock hazard exists when voltage levels greater than 30V RMS,42.4V peak, or 60VDC are present. A good safety practice is t

26、o expect that hazardous voltage is present in any unknowncircuit before measuring.Operators of this product must be protected from electric shock at all times. The responsible body must ensure that operatorsare prevented access and/or insulated from every connection point. In some cases, connections

27、 must be exposed to potentialhuman contact. Product operators in these circumstances must be trained to protect themselves from the risk of electric shock.If the circuit is capable of operating at or above 1000 volts, no conductive part of the circuit may be exposed.Do not connect switching cards di

28、rectly to unlimited power circuits. They are intended to be used with impedance limited sourc-es. NEVER connect switching cards directly to AC mains. When connecting sources to switching cards, install protective de-vices to limit fault current and voltage to the card.Before operating an instrument,

29、 make sure the line cord is connected to a properly grounded power receptacle. Inspect the con-necting cables, test leads, and jumpers for possible wear, cracks, or breaks before each use.When installing equipment where access to the main power cord is restricted, such as rack mounting, a separate m

30、ain input pow-er disconnect device must be provided, in close proximity to the equipment and within easy reach of the operator.For maximum safety, do not touch the product, test cables, or any other instruments while power is applied to the circuit undertest. ALWAYS remove power from the entire test

31、 system and discharge any capacitors before: connecting or disconnecting ca-bles or jumpers, installing or removing switching cards, or making internal changes, such as installing or removing jumpers.Do not touch any object that could provide a current path to the common side of the circuit under te

32、st or power line (earth) ground.Al-waysmakemeasurementswithdryhandswhilestandingonadry,insulatedsurfacecapableofwithstandingthevoltagebeingmeasured.The instrument and accessories must be used in accordance with its specications and operating instructions or the safety of theequipment may be impaired

33、.Do not exceed the maximum signal levels of the instruments and accessories, as dened in the specications and operating in-formation, and as shown on the instrument or test xture panels, or switching card.When fuses are used in a product, replace with same type and rating for continued protection ag

34、ainst re hazard.Chassis connections must only be used as shield connections for measuring circuits, NOT as safety earth ground connections.If you are using a test xture, keep the lid closed while power is applied to the device under test. Safe operation requires the useof a lid interlock.If a screw

35、is present, connect it to safety earth ground using the wire recommended in the user documentation.symbol on an instrument indicates that the user should refer to the operating instructions located in the manual.symbol on an instrument shows that it can source or measure 1000 volts or more, includin

36、g the combined effect of!TheThenormal and common mode voltages. Use standard safety precautions to avoid personal contact with these voltages.The WARNING heading in a manual explains dangers that might result in personal injury or death. Always read the associatedinformation very carefully before pe

37、rforming the indicated procedure.The CAUTION heading in a manual explains hazards that could damage the instrument. Such damage may invalidate the war-ranty.Instrumentation and accessories shall not be connected to humans.Before performing any maintenance, disconnect the line cord and all test cable

38、s.To maintain protection from electric shock and re, replacement components in mains circuits, including the power transformer,test leads, and input jacks, must be purchased from Keithley Instruments. Standard fuses, with applicable national safety ap-provals, may be used if the rating and type are

39、the same. Other components that are not safety related may be purchased fromother suppliers as long as they are equivalent to the original component. (Note that selected parts should be purchased onlythrough Keithley Instruments to maintain accuracy and functionality of the product.) If you are unsu

40、re about the applicabilityof a replacement component, call a Keithley Instruments ofce for information.To clean an instrument, use a damp cloth or mild, water based cleaner. Clean the exterior of the instrument only. Do not applycleaner directly to the instrument or allow liquids to enter or spill o

41、n the instrument. Products that consist of a circuit board withno case or chassis (e.g., data acquisition board for installation into a computer) should never require cleaning if handled accord-ing to instructions. If the board becomes contaminated and operation is affected, the board should be retu

42、rned to the factory forproper cleaning/servicing.11/01Table of Contents1 Getting StartedGeneral information . 1-2Warranty information 1-2Contact information 1-2Safety symbols and terms . 1-2Inspection 1-3Options and accessories 1-3Plug-in switching modules 1-3Connector and adapter kits for switching

43、 modules 1-4Cables and adapters (GPIB and trigger link) . 1-4Rack mount kits . 1-5Carrying case . 1-5Model 2700 features . 1-5Plug-in switching modules . 1-6Pseudocards . 1-8Identifying installed switching modules . 1-8Front and rear panel familiarization . 1-8Front panel summary 1-8Rear panel summa

44、ry . 1-12Power-up 1-13Line power connection 1-13Line frequency 1-14Setting line voltage and replacing fuse . 1-15Power-up sequence . 1-16Keyclick 1-16Remote programming 1-17Display . 1-17Status and error messages . 1-17Remote programming display 1-17Display commands . 1-17DISPlay:TEXT:DATA . 1-18DIS

45、Play:TEXT:STATe ON | OFF. 1-18DISPlay:ENABle ON | OFF 1-18Programming example . 1-18Defaults and user setups . 1-19Saving and restoring setups 1-20Saving a user setup 1-20Saving a power-on setup 1-20Restoring a setup 1-20Remote programming default and user setups . 1-24Programming example . 1-24Remo

46、te programming information . 1-25Quick start exercises . 1-25Basic DMM measurements front panel inputs . 1-26Exercise 1 Basic DMM measurements . 1-27Closing and opening channels systemchannel operation . 1-28Close/open operation 1-29Exercise 2 Closing and opening channels(system channel operation) 1

47、-31Simple scanning 1-31Exercise 3 Simple scanning 1-33Trigger and return readings remote programming . 1-34Exercise 4 Trigger and return a single reading 1-34Exercise 5 Trigger and return multiple readings . 1-34Exercise 6 Return a single reading(continuous triggering) 1-342 Closing and Opening Swit

48、ching Module ChannelsClose/open overview 2-2Switching module installation and connections . 2-3Module installation 2-3Connections . 2-4Pseudocards . 2-5Channel assignments 2-5System channel operation . 2-62-wire functions . 2-74-wire functions (paired channels) 2-8Controlling the system channel . 2-

49、9 and keys . 2-9CLOSE key (SINGLE menu option) . 2-10OPEN key (ALL menu option) 2-11Remote programming system channelcontrol commands . 2-11Multiple channel operation . 2-13Controlling multiple channels . 2-14CLOSE key (MULTI menu option) . 2-15OPEN key . 2-15Remote programming Multiple channelcontrol commands . 2-16Multiple channel operation anomalie