收藏 分享(赏)

sscal spikesafe calibrator.pdf

上传人:weiwoduzun 文档编号:1753859 上传时间:2018-08-22 格式:PDF 页数:2 大小:114KB
下载 相关 举报
sscal spikesafe calibrator.pdf_第1页
第1页 / 共2页
sscal spikesafe calibrator.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、ChannelOutputs+(1 to 8 )SSCalC a lib ra to rEthernetChannelOutputs-(1 to 8 )EthernetEthernetSwitchEthernetEthernetPrecisionVoltmeterSpikeSafeC urrentSourceModuleto b ec a lib ra te dSSCALsoftw areapplicationon PC Simple, easy to use, intuitive Ensure accurate measurements Traceability allows correla

2、tion Two modes: Check calibration Calibrate Rapid calibration ( 3 minutes) One calibrator multiple SpikeSafes SSCAL SpikeSafe Calibrator SpikeSafe Calibrator Block Diagram Copyright 2009, Vektrex, Version 1.1 11/10/2009 SSCAL Calibrator System integrates easy to use software application, precision v

3、oltmeter and calibration electronics Simple Connection, Calibrate in Place SSCAL supports calibration in-situ or off-site. For in-situ use, only one cable is necessary connecting the SpikeSafe module to the SSCAL. TO use, confirm Ethernet connection with the calibration software application and star

4、t the calibration application. The calibration begins execution and completes within minutes. There is no need to move the SS200 module. Eliminates Downtime, Shipping Costs By calibrating SS200 modules in place, shipping costs are eliminated along with system downtime. Calibration may be performed d

5、uring scheduled factory maintenance times when SpikeSafe modules are not being used for critical tasks. Easy To Use SSCAL Software The intuitive SSCAL application is very easy to use. It installs quickly on the existing system computer or an external calibration computer. The software application au

6、tomatically sweeps each SpikeSafe channel comparing the actual current with the programmed/expected value. If Calibrate mode is active, calibration factors are calculated and downloaded into SpikeSafe flash memory. Calibration results are displayed in a graphic form allowing visual verification. Rem

7、ove Uncertainty Vektrex SSCAL calibrator system simplifies calibration of SpikeSafe modules ensuring functionality and current accuracy. An easy to use software application makes available two modes: Check Calibration and Calibrate. Check Calibration checks the accuracy of a SpikeSafe module compari

8、ng readings to a known traceable standard and verifying that each source channel performs over its entire current range. Expected and actual values are graphically displayed for visual verification. Calibration mode removes calibration inaccuracies that can build up over time assuring the SpikeSafe

9、is ready to support present and future testing. Calibration factors are downloaded restoring the SpikeSafe module to its original factory specifications. For more information see 100V-240V, 50-60 Hz AC adapter SSCAL SpikeSafe Calibrator For more information see Specifications General Models Suppor

10、ted: SS100 SS200-500mA, -5A, -10A SS200 - Common Anode SS200FP Fast Pulse SS200HC High Current Supplied Cables: Current output cable (3 meter) Ethernet Load/Measurement Current Measurement Accuracy: 0.1% Input Power: 90-240VAC 50-60 Hz, 28W for Measurement System, 50W for Air-cooled Load Input Power

11、 Connector: Universal Input Socket Physical Air-Cooled Load & Measurement System: 2U, half width table top units Software Modes: Check Calibration, Calibrate and Set Factors Calibration Time: Under 2 minutes for 8 channels Requirements: Windows XP with .NET framework. Installer and CD Other Warranty

12、: 1 year Recommended Calibration Interval: 1 year Ordering Information Part Number Description SSCAL-CC SpikeSafe Calibration System includes Measurement System, Load, Cables, and SSCAL Software CC indicates country code. Services SSCAL-CERT Calibration Certificate SSCAL-SRVC Calibration service Sho

13、wn above is the Check Calibration view. Check Calibration quickly checks the accuracy of each SpikeSafe channel comparing reading to a known traceable standard. Both source current and monitor output are checked. Expected and actual results are graphically displayed for visual verification. Shown ab

14、ove is the Calibration view. Calibration mode removes inaccuracies. During calibration mode, the SSCAL software application sweeps each channel comparing the actual current with the programmed/expected value. Calibration factors are calculated and downloaded into SpikeSafe flash memory ensuring SpikeSafe accuracy. Check Calibration Mode Calibration Mode