1、Dear users of Inspur server:Sincerely thank you for selection of Inspur server!This manual introduces the technical characteristics and the system installation and setup of the server, and helps you to particularly understand and expediently use this server.Please deliver the package of our product
2、to the waste recycling station for recycling, in favor of pollution prevent and benefit the humankind.This manual is the property of the Inspur Group Co., Ltd.This User Manual is not to be copied by any group or person in any manner without the consent of Inspur Group Co., Ltd. The Inspur Group Co.,
3、 Ltd. reserves the right of revise this manual momentarily.Any alteration about the content of this manual will be noticed.Please contact Inspur Group Co., Ltd., if you have any questions or advice about this manual.Inspur Group Co., Ltd.Nov. 2014and “Xeon” are registered trade marks of Inspur Group
4、 Co., Ltd. All the other trademarks or registered trademarks mentioned in this manual are possessed by r their respective owners.Copyright IntroductionDocument version: V1.0Date: 5th Dec. 2014Document Introduction: The 1st formal issuance.AbstractThe manual introduces issues closely related to maint
5、enance such as specification, hardware operation, software configuration, service terms, fault diagnosis etc. of the server.Readers of this guide will be deemed to have abundant knowledge about the server product, and will not cause any personal injury or product damage during operation and maintena
6、nce, for sufficient trainings received by them.Target AudienceThis manual mainly adapts to the following personnel: Technical support engineers Product maintenance engineersIt is suggested that server maintenance operation shall be carried out by professional engineers with related server knowledge
7、via referring to this manual.Table of ContentCOPYRIGHT INTRODUCTION.2ABSTRACT .2TARGET AUDIENCE .2TABLE OF CONTENT .31 SAFETY INTRODUCTION .52. PRODUCT SPECIFICATION INTRODUCTION.112.1 Introduction.112.2 Features and Specification .132.3 Front Panel .162.4 Rear Panel .232.5 Mainboard Layout.242.6 Ma
8、inboard Jumper Introduction.273 BIOS CONFIGURATION.283.1 System BIOS Configuration Methods .283.2 BIOS Configuration .303.3 Firmware Update.804 BMC CONFIGURATION .854.1 Introduction.854.2 Functional Modules.864.3 Web Interface Introduction .874.4 Remote Control .924.5 Power Supply and Heat Radiation
9、 .944.6 BMC Configuration .954.7 Logs.994.8 Fault Diagnosis .1004.9 System Maintenance .1024.10 Command Line Function Introduction.1034.11 Time Zone Table.11005 HARDWARE MAINTENANCE .1125.1 Tool Preparation.1125.2 Parts Replacement.1136. FREQUENT FAULTS, DIAGNOSIS AND TROUBLESHOOTING.1316.1 Frequent
10、 Faults.1316.2 Diagnosis and Exclusion Instructions .1327 SERVICE INTRODUCTION .13557.1 How to Obtain Help .13557.2 Various Methods to Contact Inspur Technical Support.13668 SPECIFICATIONS .13888.1 USA FCC Statement .13888.2 CE Statement of EU.13998.3 China CCC .13998.4 China Environmental Symbols .
11、13991 Safety IntroductionWarning: the following warnings show that there are potential dangers that may cause property loss, personal injury or death:1. The power supply equipment in the system may generate high voltage and dangerous electrical energy and thus cause personal injury. Please do not di
12、smount the cover of the host or to dismount and replace any component in the system by yourself, unless otherwise informed by Inspur; only maintenance technicians trained by Inspur have the right to disassemble the cover of the host, dismount and replace the internal components.2. Please connect the
13、 equipment to appropriate power supply, and the power should be supplied by external power supply which is indicated on the rated input label. To prevent your equipment from damages caused by momentary spike or plunge of the voltage, please use relevant voltage stabilizing equipment or uninterruptib
14、le power supply equipment.3. If extended cables are needed, please use the three-core cables matched with correct earthed plug, and check the ratings of the extended cables to make sure that the sum of rated current of all products inserted into the extended cables do not exceed 80% of the limits of
15、 the rated currents of the extended cables.4. Please be sure to use the supplied power supply component, such as power lines, power socket (if supplied with the equipment) etc. For the safety of equipment and the user, do not replace randomly power cables or plugs.5. To prevent electric shock danger
16、s caused by leakage in the system, please make sure that the power cables of the system and peripheral equipment are correctly connected to the earthed power socket. Please connect the three-core power line plug to the three-core AC power socket that is well earthed and easy to access, be sure to us
17、e the earthing pin of power lines and do not use the patch plug or the earthing pin unplugged with cables. In case of the earthing conductors not installed and it is uncertain whether there are appropriate earthing protections, please do not operate or use the equipment. Contact and consult with the
18、 electrician.6. To avoid short circuit of internal components and fire or electric shock hazards, please do not fill any object into the open pores of the system.7. Please place the system far away from the cooling plate and at the place with heat sources, and be sure not to block the air vents.8. B
19、e sure not to scatter food or liquid in the system or on other components, and do not use the product in humid and dusty environment.9. The replacement of batteries with those of another model may cause explosion. When replacement of batteries is required, please consult first the manufacturer and c
20、hoose batteries of the same or a similar model recommended by the manufacturer. Do not dismount, extrude and pink the batteries or make the external connection point short circuit, and do not expose them in the environment over 60C. Never throw them into fire or water. Please do not try to open or r
21、epair the batteries, and be sure to reasonably deal with the flat batteries and do not put the fl at batteries, the circuit boards that may include the batteries and other components with other wastes. For relevant battery recovery, please contact the local waste recovery and treatment mechanism.10.
22、 Before installing equipment in the chassis, please install front and side supporting feet on the independent chassis; for cabinet connecting with other chassis, it shall install the front supporting foot first. If you fail to install correspondingly the supporting foot before installing equipment i
23、n the chassis, it may cause the cabinet to turn over in some cases, and thus may cause personal injury. Therefore, it is necessary to install supporting feet before installing equipment in the chassis. After installing the equipment and other components in the chassis, it can only pull out one compo
24、nent from the cabinet through its sliding component at one time. Pulling out several components at the same time may lead the cabinet to turn over and cause serious personal injury.11. Please do not move the chassis independently. Considering the height and weight of the chassis, at least two people
25、 are needed to complete its movement.12. Please do not carry out direct contact operation on power copper busbar when the cabinet is powered on, and it is prohibited to carry out direct short circuit of power copper busbar.13. The product is Grade A product, and in the living environment, it may cau
26、se radio interference. In such case, it may need the user to take feasible measures for the interference.Note: In order to help you use the equipment, the following considerations can help avoid the occurrence of problems that may damage the components or cause data loss etc.1. In case of the follow
27、ing cases, please unplug the power line plug of products from the power socket and contact customer service department of Inspur:1) The power cables, extended cables or power plugs are damaged.2) The products get wet by water.3) The products have fallen off or been damaged.4) Objects fall into the p
28、roducts.5) When operating according to the operation instructions, the products cannot function normally.2. If the system becomes damp, please dispose according to the following steps:1) Switch off the power supplies of the system and the equipment, disconnect them with the power socket, wait for 10
29、 to 20 minutes, and then open the cover of the host.2) Move the equipment to the ventilation place to dry the system at least for 24 hours and make sure that the system is fully dried.3) Close the cover of the host, re-connect the system to the power socket, and then start the equipment.4) In case o
30、f operation failure or abnormal situation, please contact Inspur and get technical support.3. Pay attention to the position of the system cables and power cables, wire them in places not to be stepped on or knocked down and ensure not to place other objectives on the cables.4. Before dismounting the
31、 cover of host or contacting the internal components, you shall cool down the equipment first; to avoid damaging the main-board, please power off the system and wait for 5 seconds, and then dismount the components from the main-board or disconnect the connection of peripheral equipment of the system
32、.5. If there are modulator-demodulator, telecommunication or local area network options in the equipment, please pay attention to the following matters:1) In case of thunder and lightning weather, please do not connect or use the modulator-demodulator. Otherwise, it may be subject to lightning strik
33、e.2) Never connect or use modulator-demodulator in moist environment.3) Never insert the modulator-demodulator or telephone cables to the socket of network interface controller (NIC).4) Before unpacking the product package, contacting or installing internal components or contacting un-insulated cabl
34、es or jacks of the modulator-demodulator, please disconnect the modulator-demodulator cables.6. In order to prevent the electrostatic discharge from damaging the electronic components in the equipment, please pay attention to the following matters:1) You shall conduct off the static electricity on t
35、he body before dismounting or contacting any electronic component in the equipment. You can conduct off the static electricity on the body by contacting the metal earthing objects (such as the unpainted metal surface on the chassis) to prevent the static electricity on the body from conducting itsel
36、f to the sensitive components.2) For electrostatic sensitive components not ready to be installed for application, please do not take them out from the antistatic package materials.3) During the work, please touch the earthing conductor or the unpainted metal surface on the cabinet regularly to cond
37、uct off the static electricity on the body that may damage the internal components.7. When dismounting the internal components with the approval of Inspur, please pay attention to the following matters:1) Switch off the system power supply and disconnect the cables, including disconnecting any conne
38、ction of the system. When disconnecting the cables, please grab the connector of cables and plug it out, and never pull the cables.2) Before dismounting the cover of cabinet or touching the internal components, the products need to be cooled down.3) Before dismounting and touching any electronic com
39、ponent in the equipment, you shall conduct off the static electricity on the body by touching the metal earthingobjectives.4) During the dismounting process, the operation shall not be too big, so as to prevent damage to the components or scratching of the arms.5) Carefully deal with the components and plug-in cards, and please never touch, the components or connection points on the plug-in cards. When taking the plug-in cards or