1、标准文档外 文 翻 译院 (系)专业班级姓 名学 号指导教师年 月 日标准文档Programmable designed for electro-pneumatic systems controllerJohn F.WakerlyThis project deals with the study of electro-pneumatic systems and the programmable controller that provides an effective and easy way to control the sequence of the pneumatic actuators
2、 movement and the states of pneumatic system. The project of a specific controller for pneumatic applications join the study of automation design and the control processing of pneumatic systems with the electronic design based on microcontrollers to implement the resources of the controller.1. Intro
3、ductionThe automation systems that use electro-pneumatic technology are formed mainly by three kinds of elements: actuators or motors, sensors or buttons and control elements like valves. Nowadays, most of the control elements used to execute the logic of the system were substituted by the Programma
4、ble Logic Controller (PLC). Sensors and switches are plugged as inputs and the direct control valves for the actuators are plugged as outputs. An internal program executes all the logic necessary to the sequence of the movements, simulates other components like counter, timer and control the status
5、of the system.With the use of the PLC, the project wins agility, because it is possible to create and simulate the system as many times as needed. Therefore, time can be saved, risk of mistakes reduced and complexity can be increased using the same elements.A conventional PLC, that is possible to fi
6、nd on the market from many companies, offers many resources to control not only pneumatic systems, but all kinds of system that uses electrical components. 标准文档The PLC can be very versatile and robust to be applied in many kinds of application in the industry or even security system and automation o
7、f buildings.Because of those characteristics, in some applications the PLC offers to much resources that are not even used to control the system, electro-pneumatic system is one of this kind of application. The use of PLC, especially for small size systems, can be very expensive for the automation p
8、roject.An alternative in this case is to create a specific controller that can offer the exactly size and resources that the project needs 3, 4. This can be made using microcontrollers as the base of this controller.The controller, based on microcontroller, can be very specific and adapted to only o
9、ne kind of machine or it can work as a generic controller that can be programmed as a usual PLC and work with logic that can be changed. All these characteristics depend on what is needed and how much experience the designer has with developing an electronic circuit and firmware for microcontroller.
10、 But the main advantage of design the controller with the microcontroller is that the designer has the total knowledge of his controller, which makes it possible to control the size of the controller, change the complexity and the application of it. It means that the project gets more independence f
11、rom other companies, but at the same time the responsibility of the control of the system stays at the designer hands2. Electro-pneumatic systemOn automation system one can find three basic components mentioned before, plus a logic circuit that controls the system. An adequate technique is needed to
12、 project the logic circuit and integrate all 标准文档the necessary components to execute the sequence of movements properly.For a simple direct sequence of movement an intuitive method can be used 1, 5, but for indirect or more complex sequences the intuition can generate a very complicated circuit and
13、signal mistakes. It is necessary to use another method that can save time of the project, make a clean circuit, can eliminate occasional signal overlapping and redundant circuits. The presented method is called step-by-step or algorithmic 1, 5, it is valid for pneumatic and electro-pneumatic systems
14、 and it was used as a base in this work.The method consists of designing the systems based on standard circuits made for each change on the state of the actuators, these changes are called steps. 标准文档The first part is to design those kinds of standard circuits for each step, the next task is to link
15、 the standard circuits and the last part is to connect the control elements that receive signals from sensors, switches and the previous movements, and give the air or electricity to the supply lines of each step. In Figs. 1 and 2 the standard circuits are drawn for pneumatic and electro-pneumatic s
16、ystem 8. It is possible to see the relations with the previous and the next steps. 3. The method applied inside the controller The result of the method presented before is a sequence of movements of the actuator that is well defined by steps. It means that each change on the position of the actuator
17、s is a new state of the system and the transition between states is called step. The standard circuit described before helps the designer to define the states of the systems and to define the condition to each change 标准文档between the states. In the end of the design, the system is defined by a sequen
18、ce that never chances and states that have the inputs and the outputs well defined. The inputs are the condition for the transition and the outputs are the result of the transition. All the configuration of those steps stays inside of the microcontroller and is executed the same way it was designed.
19、 The sequences of strings are programmed inside the controller with 5 bytes; each string has the configuration of one step of the process. There are two bytes for the inputs, one byte for the outputs and two more for the other configurations and auxiliary functions of the step. After programming, th
20、is sequence of strings is saved inside of a non-volatile memory of the microcontroller, so they can be read and executed. The controller task is not to work in the same way as a conventional PLC, but the purpose of it is to be an example of a versatile controller that is design for an specific area.
21、 A conventional PLC process the control of the system using a cycle where it makes an image of the inputs, execute all the conditions defined by the configuration programmed inside, and then update the state of the outputs. This controller works in a different way, where it read the configuration of
22、 the step, wait the condition of inputs to be satisfied, then update the state or the outputs and after that jump to the next step and start the process again. It can generate some limitations, as the fact that this controller cannot execute, inside the program, movements that must be repeated for s
23、ome time, but this problem can be solved with some external logic components. Another limitation is that the controller cannot be applied on systems that have no sequence. These limitations are a characteristic of the system that must be analyzed for each application.标准文档4. Characteristics of the co
24、ntroller The controller is based on the MICROCHIP microcontroller PIC16F877 6,7 with 40 pins, and it has all the resources needed for this project .It has enough pins for all the components, serial communication implemented in circuit, EEPROM memory to save all the configuration of the system and th
25、e sequence of steps. For the execution of the main program, it offers complete resources as timers and interruptions. The list of resources of the controller was created to explore all the capacity of the microcontroller to make it as complete as possible. During the step, the program chooses how to
26、 use the resources reading the configuration string of the step. This string has two bytes for digital inputs, one used as a mask and the other one used as a value expected. One byte is used to configure the outputs value. One bytes more is used for the internal timer , the analog input or time-out.
27、 The EEPROM memory inside is 256 bytes length that is enough to save the string of the steps, with this characteristic it is possible to save between 48 steps (Table 1).The controller (Fig.3) has also a display and some buttons that are used with an interactive menu to program the sequence of steps
28、and other configurations.标准文档4.1. Interaction components For the real application the controller must have some elements to interact with the final user and to offer a complete monitoring of the system resources that are available to the designer while creating the logic control of the pneumatic sys
29、tem (Fig.3):Interactive mode of work; function available on the main program for didactic purposes, the user gives the signal to execute the step.LCD display, which shows the status of the system, values of inputs, outputs, timer and statistics of the sequence execution.Beep to give important alerts
30、, stop, start and emergency. Leds to show power on and others to show the state of inputs and outputs. 标准文档4.2. Security To make the final application works property, a correct configuration to execute the steps in the right way is needed, but more then that it must offer solutions in case of bad fu
31、nctioning or problems in the execution of the sequence. The controller offers the possibility to configure two internal virtual circuits that work in parallel to the principal. These two circuits can be used as emergency or reset buttons and can return the system to a certain state at any time 2. Th
32、ere are two inputs that work with interruption to get an immediate access to these functions. It is possible to configure the position, the buttons and the value of time-out of the system. 4.3. User interface The sequence of strings can be programmed using the interface elements of the controller. A
33、 Computer interface can also be used to generate the user program easily. With a good documentation the final user can use the interface to configure the strings of bytes that define the steps of the sequence. But it is possible to create a program with visual resources that works as a translator to
34、 the user, it changes his work to the values that the controller understands.To implement the communication between the computer interface and the controller a simple protocol with check sum and number of bytes is the minimum requirements to guarantee the integrity of the data. 4.4. Firmware The mai
35、n loop works by reading the strings of the steps from the EEPROM memory that has all the information about the steps. In each step, the status of the system is saved on the memory and it is shown on the display too. Depending of the user configuration, it can use the interruption to work with the em
36、ergency circuit or 标准文档time-out to keep the system safety. In Fig.4,a block diagram of micro controller main program is presented.5. Example of electro-pneumatic system The system is not a representation of a specific machine, but it is made with some common movements and components found in a real
37、one. The system is composed of four actuators. The actuators A, B and C are double acting and D-single acting. Actuator A advances and stays in specified position till the end of the cycle, it could work fixing an object to the next action for example (Fig. 5) , it is the 标准文档first step. When A reac
38、hes the end position, actuator C starts his work together with B, making as many cycles as possible during the advancing of B. It depends on how fast actuator B is advancing; the speed is regulated by a flowing control valve. It was the second step. B and C are examples of actuators working together
39、, while B pushes an object slowly, C repeats its work for some time.When B reaches the final position, C stops immediately its cycle and comes back to the initial position. The actuator D is a single acting one with spring return and works together with the back of C, it is the third step. D works m
40、aking very fast forward and backward movement, just one time. Its backward movement is the fourth step. D could be a tool to make a hole on the object.When D reaches the initial position, A and B return too, it is the fifth step. Fig. 6 shows the first part of the designing process where all the mov
41、ements of each step should be defined 2. (A+) means that the actuator A moves to the advanced position and (A) to the initial 标准文档position. The movements that happen at the same time are joined together in the same step. The system has five steps. These two representations of the system (Figs. 5 and
42、 6) together are enough to describe correctly all the sequence. With them is possible to design the whole control circuit with the necessary logic components. But till this time, it is not a complete system, because it is missing some auxiliary elements that are not included in this draws because th
43、ey work in parallel with the main sequence. These auxiliary elements give more function to the circuit and are very important to the final application; the most important of them is the parallel circuit linked with all the others steps. That circuit should be able to stop the sequence at any time an
44、d change the state of the actuators to a specific position. This kind of circuit can be used as a reset or emergency buttons.The next Figs. 7 and 8 show the result of using the method without the controller. These pictures are the electric diagram of the control circuit of the example, including sen
45、sors, buttons and the coils of the electrical valves.标准文档标准文档The auxiliary elements are included, like the automatic/manual switcher that permit a continuous work and the two start buttons that make the operator of a machine use their two hands to start the process, reducing the risk of accidents. 6
46、. Changing the example to a user program In the previous chapter, the electro-pneumatic circuits were presented, used to begin the study of the requires to control a system that work with steps and must offer all the functional elements to be used in a real application. But, as explained above, usin
47、g a PLC or this specific controller, the control becomes easier 标准文档and the complexity can be increase also. Table 2 shows a resume of the elements that are necessary to control the presented example. With the time diagram, the step sequence and the elements of the system described in Table 2 and Fi
48、gs. 5 and 6 it is possible to create the configuration of the steps that can be sent to the controller (Tables 3 and 4).While using a conventional PLC, the user should pay attention to the logic of the circuit when drawing the electric diagram on the interface (Figs. 7 and 8), using the programmable
49、 controller, described in this work, the user must know only the concept o f the method and program only the configuration of each step.It means that, with a conventional PLC, the user must draw the 标准文档relation between the lines and the draw makes it hard to differentiate the steps of the sequence. Normally, one needs to execute a simulation on the interface to find mistakes on the logicThe new programming allows that the configuration of the steps be separated, like described by the method. The sequence is defined by itself and the steps are described only by the inpu